Mennekes AMTRON Manuel D'utilisation Et Guide D'installation page 61

Masquer les pouces Voir aussi pour AMTRON:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 111
Enable cache
Setting that specifies whether an
internal cache will be used for the
RFID-UID
List of entries in
Listing of the RFID-UIDs present in
cache
the internal cache
Cache expiry mode
The expiration date of cache ent-
ries, if the OCPP expiration date has
not been specified by the Backend-
System
Local fixed authoriza-
Setting that specifies whether a
tion list
local authorisation list will be used
for the RFID-UIDs
List of entries in fixed
Listing of the RFID-UIDs in the local
local list (FLL)
authorisation list
RFID Tag letter case
Setting that specifies how the RFID-
UIDs will be processed by the tag
management
Send Authorize for
Setting that specifies whether after
RemoteStart
receipt of an OCPP RemoteStart
request, an OCPP authorisati-
on message will be sent to the
Backend-System
Stop Transaction
Setting that specifies how the
Mode
device should behave at the end of
a transaction
Restart transaction
Setting that specifies whether a
after power loss
transaction will be continued after a
power outage
Send informative
Setting that specifies whether infor-
StatusNotifications
mative OCPP status messages will
be sent to the Backend-System
Send error
Setting that specifies whether error-
StatusNotifications
related OCPP status messages will
be sent to the Backend-System
Send USB error
StatusNotification
Strategy for
Setting that specifies the conditions
StatusNotification
under which the charging point
state transitions
changes to the "Occupied" state
"Off": RFIDs will not be added to the
internal cache
„ Syntax: UID1:UID2:UID3 ...
„ Max. 80 RFID-UIDs
Preset: 2038 (latest permissible time)
Authorisation
„ Syntax: UID1:UID2:UID3 ...
„ Max. 80 RFID-UIDs
Information will be provided from your
Backend sys-
Backend-System operator
tem
"Normal" unlocks and ends the trans-
action, if the plug on the vehicle has
been unplugged (set for devices with
a permanently connected charging
Charging sys-
cable)
tem
For example, temperature reports
Backend sys-
tem
Not relevant for the device
„ Only for "OCPP-S 1.5"
„ "Occupied on Charging": Occupied
when an authorisation is present
Backend sys-
and a charging cable is plugged in
tem
„ "Occupied on Authorized/Plugged":
Occupied when the charging point
is authorised or a charging cable /
vehicle is connected
EN
23

Hide quick links:

Publicité

Table des Matières
loading

Table des Matières