2.2.2 Periodic transmission

The product allows the reading and the periodic transmission of the labels of the meter according to the following diagram:
FR
EN
The data is always from the same TIC carousel, so the product waits for the beginning of a new one before reading the labels.
The parameters associated with this operating mode are:
• the acquisition period (register 320).
• the issue period (register 301).
• the definition of periodic data (registers 330 to 353).
The complete list of registers is in paragraph 3.4.
For example:
Registre
Value encoding
S320
Decimal
S301
Decimal
S330
ASCII
S331
Decimal
Product in standby
Period
reached ?
Waiting for start of TIC
carousel
Reading labels
Storing periodic data
Transmis-
sion period
reached?
Send frame 0x49
Value
Result
5
Periodic mode with an acquisition period of 5x1min = 5 minutes
2
The transmission will take place every 2 x S320 = 2x5 = 10 minutes
«HCHC»
Retrieving the label named HCHC (Off-peak Hours index)
0
The value of 0 indicates that the data must be treated as a numeric value
No
YES
No
YES