Transceiver TIC - Guide utilisateur / User guide version V2.0.0

1.4.3 Counter compatibility

Examples of counters tested by adeunis® (non-exhaustive list):
Reference
Itron ACE6000
Landis+Gyr ZMD126.02
Landis+Gyr ZMG 416
FR
Sagemcom LNE-29079
Landis+Gyr LNE-29125

2. PRODUCT OPERATION

2.1. Global Operation

EN
Important: adeunis® use the most significant byte first format.
The product has several operating modes:

2.1.1 PARK mode

The product is delivered in PARK mode, it is in standby mode and its consumption is minimal. To switch the product out of the Park* Mode pass
a magnet across (at the label level) it for a duration higher than 6 seconds. The green LED illuminates to indicate the detection of the magnet
and then flashes quickly during the product starting phase.
The device then sends its configuration and data frames (see paragraph 4.1).

2.1.2 COMMAND mode

This mode allows the user to configure the registers of the product.
To enter this mode, connect a cable to the micro-USB port of the product and enter the command mode by an AT command (see paragraph 3).

2.1.3 OPERATING mode

There are two possible modes of operation:
TEST mode:
This mode allows the user to perform tests of the product more quickly by reducing the time scales of production mode and modifying the
behavior of the LEDs (see paragraph 2.3).
PRODUCTION mode:
This mode allows the user to operate the product in its final use. It should allow a maximum of autonomy to the product.
To switch from one mode to the other the user come into command mode (paragraph 3.2) and change the value of the register S306
Command sen-
ding by serial link
COMMAND MODE
PRODUCTION
MODE S306=1
COMMAND
MODE
TEST MODE
S306=2
Type (TIC, PME-PMI, Linky)
PME/PMI
TIC BLEU
PME/PMI
Linky
Linky
PARK MODE
Presence of a magnet
on the product >6s
OPERATING MODE
(production or test)
COMMAND
MODE
The return to the pro-
duction mode is done
by the ATO command
or by disconnecting
the USB cable