Transceiver TIC - Guide utilisateur / User guide version V2.0.0

3.4. Description of the registers

On switching on the product works according to the last saved configuration (Factory Configuration if it is the first start, or if this configuration
has not been changed).
Command as Modification TTY<n>=<M> allows you to change the content of the registers: <n> representing the number of the register and
<m> the value to be assigned. This latter is either a decimal value or a Hexadecimal value consistent with the «encoding» column of the tables
below.
FR
It is imperative to save the parameters with the command AT&W before exiting the Command mode otherwise all changes will be lost.
IMPORTANT: The registers that are not documented (that can appear in the list following the AT/S command) in
the paragraphs that follow are reserved and must not be changed.

3.4.1 Function registers

EN
The list of registers below allows you to change the behavior of the product application.
Register Size
Description
(bytes)
S300
1
Transmission period of the Keep Alive
frame
S301
2
Period of issue
(periodic data)
S303
1
Activation of the acknowledged mode Decimal
S304
2
PIN code
S306
1
Global operation
S320
2
Acquisition period
S330
10
Label of the periodic data 1
S331
1
Length / type of the periodic data 1
S332
10
Label of the periodic data 2
Code
Details
Decimal
Default: 144
Min/max: 1 to 255
Unit:
x 10min if S306=1
x 20s if S306=2
Decimal
Default: 2
Min/max: 0 to 1440
Value meaning :
• 0: Disabling the periodic issue
• 1 to 1440: If the scan is continuous (S320 = 0), S301
expresses the number of minutes between each transmission.
If 320 is not 0, the transmission period = S301 x S320 minutes.
Default: 0 (deactivated)
Value: 0 (deactivated) to 1 (activated)
Decimal
Default : 0 (disabled)
Min/max: 0 to 9999
PIN code used with ATPIN command.
Value 0 disables the PIN code.
Decimal
Default: 0
Allows the product to be switched into one of the following
modes:
• 0: PARK mode
• 1: Production mode
• 2: TEST mode
Decimal
Default: 4320
Min/max: 1 to 4320
Unit: x20s
Meaning of the value :
The value of 4320 = 24h period
ASCII
Default: 0
Size: Maximum 10 characters ASCII authorized.
Decimal
Default: 0
Min/max: 0 to 38
Meaning of value:
• 0: the data must be treated as a numeric value.
• 1: the data must be treated as a timestamp*
• 2 to 38: value of the length of the ASCII string of the periodic
data 1 (if the data length is 1 caracter choose 2)
ASCII
See register details 330
Page
72
of 98