Transceiver TIC - Guide utilisateur / User guide version V2.0.0
5. PREPARATION AND CONFIGURATIONS
5.1. Disassembling the casing
The product is delivered disassembled so that you can access the lower part of the electronics. This part enables the sensor or sensors to be
connected to the screw terminals as well as access to the configuration switches.
Once assembly of the sensors has been finalized and the configuration has been carried out, the casing can be closed.
NB: Once the casing is closed, it will no longer be possible to open it without running the risk of voiding the IP67 protection index guarantee.
5.2. Fitting the packing gland seal
Before connecting your sensor's cable strands to the product's screw terminals, you must insert the packing gland's nut and the seal appropriate
for your configuration.
Three types of seals are supplied with product: For a cable with a diameter of 5 mm, for a cable with a diameter of 3 mm, and for two cables
with diameters of 2.2 mm.
Assembly procedure:
5.3. Mounting the sensor on the screw terminals
Once the nut and the packing gland seal are fitted, the sensor cables' strands can be connected to the product unit's screw terminals.
1 - Your sensor and
2 -Pass the cable
its cable
through the packing
gland nut
5.4. Cabling
5.4.1 Description of the terminal block
3 - Pass the cable
through the packing
105
gland seal
1. TIC Data
2. TIC Commun
3. TIC PowerLinky
4. RS232 RX
5. RS232 GND
6 External power supply +
7 Internal power supply -
90
4 - Pass the cable
through the LoRaWAN
SENSORS casing base
27
5 - Fit the O-ring
6 - Connect the sen-
onto the seal of the
sor cable strands to
casing base
the screw terminals
FR
EN
Page
87