LoRaWAN MODBUS MASTER - Guide utilisateur / User guide version V1.0.0

3.4. Description of the registers

On switching on the product works according to the last saved configuration (Factory Configuration if it is the first start, or if this configuration
has not been changed).
Commands such as Modification TTY<n>=<M> or ATR allow you to change the content of the registers: <n> repre-senting the number of the
register and <m> the value to be assigned. This latter is either a decimal value or a hexadecimal value consistent with the «encoding» column
of the tables below.
FR
Examples:
• ATS300=6 assigns the decimal value 6 in register 300
• ATS320=2 assigns the hexadecimal value 0x02 in register 302
It is imperative to save the parameters with the command AT&W before exiting the Command mode otherwise all changes will be lost.
EN
IMPORTANT: The registers that are not documented (that can appear in the list following the AT/S command) in
the paragraphs that follow are reserved and must not be changed.

3.4.1 Function registers

The list of registers below allows you to change the behaviour of the product application.
Registre
Taille (octets)
300
301
303
304
306
320
Description
1
Transmission period of the
Keep Alive frame
2
Transmission period of data
sensors
1
Confrmed mode activation
1
PIN code
2
Global operation
2
Data acquisition period for
alarm
Codage
Détails
Decimal
Default: 144
Min/max: 1 à 255
Unit:
x 10min if S306=1
x 20s if S306=2
Decimal
Default: 4320
Min/max : 1 to 4320
Unit: x 20 seconds
The value 4320 is equivalent to a period of 24 hours.
Decimal
Default value : 0 (desactivated)
Values : 0 (desactivated) to 1 (activated)
Decimal
Default : 0 (disabled)
Min/max : 0 to 9999
PIN code used with ATPIN command.
Value 0 disables the PIN code.
Decimal
Default: 0
Allows the product to be switched into one of the fol-
lowing modes:
• 0: PARK mode
• 1: Production mode
• 2: TEST mode
Decimal
Default: 4320
Min/max : 1 to 4320
Unit: x 20 seconds
The value 4320 is equivalent to a period of 24 hours.
Page
58
of 80