2.2. Application operation
2.2.1 Periodic transmission
The product allows the measurement and the periodic transmission of the values of the sensors according to the following diagram:
Period
No
reached
?
Yes
Number of
savings be-
fore sending
=1?
Yes
Send frame 0x46
Eg:
Register
Value encoding
S301
Decimal
S321
Decimal
S320
Hexadecimal
S322
Hexadecimal
N.B: for a periodical transmission without historisation of the data, S301 must be egal to 1.
Product in standby
Detected
and validat-
ed pulse
?
Counting
of the impulse
No
See paragraph about periodical
transmission with historic
Value
1
43200
0x39
0x57
The settings associated with this mode of operation
are:
•
Transmission frequency (register S301)
No
•
Historisation period of the data (register S321)
•
Enabling and Configuring inputs (register S320)
•
Anti-bounce timer period (registers S322)
Yes
Result
Number of historisation (savings) to be done before sending
Period of historisation/saving of the data (43200x 2 seconds = 24h).
Channel A :
•
Activated
•
Meter other than gas
•
Tamper input activated
Channel B :
•
Activated
•
Gas meter
•
Tamper input disabled
Anti-rebound :
•
Channel A = 500ms
•
Channel B = 100ms
FR
EN
Page
41