Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

Sigfox Smart Building MOTION
Transceiver Presence and Luminosity
Guide utilisateur / User Guide
Version 1.0.1
Adeunis
283 rue Louis Néel - Parc Technologique Pré Roux
38920 CROLLES - France
www.adeunis.com
DISTRIBUTED BY TEXIM EUROPE

Publicité

Table des Matières
loading

Sommaire des Matières pour ADEUNIS Sigfox Smart Building MOTION

  • Page 1 Sigfox Smart Building MOTION Transceiver Presence and Luminosity Guide utilisateur / User Guide Version 1.0.1 Adeunis 283 rue Louis Néel - Parc Technologique Pré Roux 38920 CROLLES - France www.adeunis.com DISTRIBUTED BY TEXIM EUROPE...
  • Page 2 Ninguna parte de este documento puede ser reproducida o transmitida (en fotocopias electrónico o en papel, o) sin el acuerdo adeunis®. Este documento puede ser modifi cada sin previo aviso. Todas las marcas comer- ciales mencionadas en esta guía son el tema de los derechos de propiedad intelectual.
  • Page 3: Table Des Matières

    Sigfox Smart Building MOTION - Guide utilisateur / User guide version V1.0.1 TABLE DES MATIÈRES FRANÇAIS INFORMATIONS PRODUITS ET RÉGLEMENTAIRES PRÉSENTATION DU PRODUIT 1.1. Description générale 1.2. Encombrement 1.3. Carte électronique 1.4. Compatibilité plateforme KARE 1.5. Spécifications Techniques 1.5.1 Caractéristiques générales 1.5.2 Autonomie...
  • Page 4 Sigfox Smart Building MOTION - Guide utilisateur / User guide version V1.0.1 ENGLISH PRODUCTS AND REGULATORY INFORMATION DEVICE OVERVIEW 1.1. General description 1.2. Dimensions 1.3. Circuit board 1.4. KARE platform compatibility 1.5. Technical Specifications 1.5.1 General characteristics 1.5.2 Autonomy 1.5.3 Digital input interfaces 1.5.4 Characteristics of the embedded sensors...
  • Page 5: Français

    Sigfox Smart Building MOTION - Guide utilisateur / User guide version V1.0.1 FRANÇAIS Page of 83 DISTRIBUTED BY TEXIM EUROPE...
  • Page 6: Informations Produits Et Réglementaires

    Ce document et l’utilisation de toute information qu’il contient, est soumis à l’acceptation des termes et conditions Adeunis. Adeunis ne donne aucune garantie sur l’exactitude ou l’exhaustivité du contenu de ce document et se réserve le droit d’apporter des modifi cations aux spécifi cations et descriptions de produit à tout moment sans préavis.
  • Page 7 Sigfox Smart Building MOTION - Guide utilisateur / User guide version V1.0.1 Déclaration UE de Conformité Nous Adeunis 283 rue LOUIS NEEL 38920 Crolles, France 04.76.92.01.62 www.adeunis.com Déclarons que la DoC est délivrée sous notre seule responsabilité et fait partie du produit suivant : Modèle produit :...
  • Page 8 notifi...
  • Page 9 Sigfox Smart Building MOTION - Guide utilisateur / User guide version V1.0.1 RECOMMANDATIONS ENVIRONNEMENTALES Tous les matériaux d’emballage superfl us ont été supprimés. Nous avons fait notre possible afi n que l’emballage soit facilement séparable en trois types de matériaux : carton (boîte), polystyrène expansible (matériel tampon) et poly- éthylène (sachets, feuille de protection en mousse).
  • Page 10 Sigfox Smart Building MOTION - Guide utilisateur / User guide version V1.0.1 RECOMMANDATIONS D’USAGE • Avant d’utiliser le système, vérifi ez si la tension d’alimentation fi gurant dans son manuel d’utilisation corres- pond à votre source. Dans la négative, consultez votre fournisseur.
  • Page 11: Présentation Du Produit

    1. PRÉSENTATION DU PRODUIT Description : • Le Sigfox Smart Building MOTION d’adeunis® est un émetteur radio prêt à l’emploi permettant de détecter la présence d’une source de chaleur et de déterminer le niveau de luminosité dans une pièce. •...
  • Page 12: Encombrement

    Sigfox Smart Building MOTION - Guide utilisateur / User guide version V1.0.1 1.2. Encombrement Valeurs en millimètres 1.3. Carte électronique Antenne interne Module RF ProtocoleSigfox Bornier Port USB pour configuration produit Page of 83 DISTRIBUTED BY TEXIM EUROPE...
  • Page 13: Compatibilité Plateforme Kare

    Sigfox Smart Building MOTION - Guide utilisateur / User guide version V1.0.1 1.4. Compatibilité plateforme KARE Le produit Sigfox Smart Building MOTION est compatible avec la plateforme KARE. La plateforme KARE est un service de device management vous permettant de mettre en place une solution IoT globale.
  • Page 14: Interfaces D'entrée Digitale

    Sigfox Smart Building MOTION - Guide utilisateur / User guide version V1.0.1 1.5.3 Interfaces d’entrée digitale Le schéma de principe des interfaces d’entrée digitale est le suivant : Valeurs absolues maximales Unité Tension minimale d’entrée - 0,7 Tension maximale d’entrée Caractéristiques électriques...
  • Page 15: Fonctionnement Du Produit

    Sigfox Smart Building MOTION - Guide utilisateur / User guide version V1.0.1 2. FONCTIONNEMENT DU PRODUIT 2.1. Modes de fonctionnement NOTE IMPORTANTE : adeunis® utilise le format de données Big-Endian Le produit dispose de plusieurs modes de fonctionnement : MODE PARC...
  • Page 16: Trois Modes De Transmissions Pour Correspondre Au Besoin

    Sigfox Smart Building MOTION - Guide utilisateur / User guide version V1.0.1 2.1.5 Trois modes de transmissions pour correspondre au besoin Le produit permet de détecter la présence dans une pièce et le niveau de luminosité, de sauvegarder cette information et de l’envoyer selon trois modes d’émission.
  • Page 17 Sigfox Smart Building MOTION - Guide utilisateur / User guide version V1.0.1 Démarche à suivre pour programmer les registres en fonction du mode choisi. Dans quel mode je veux mettre mon produit ? Alarme sur dépassement Périodique Périodique de seuil Alarme Quelle est ma période entre chaque relevé...
  • Page 18 Sigfox Smart Building MOTION - Guide utilisateur / User guide version V1.0.1 Exemple de configurations possibles : Cas voulu (hors 100% événementiel) Configuration Nombre théorique de associée trame périodiques envoyées par jour • Relevé/scrutation : 10 minutes • 321 = 300 •...
  • Page 19 Sigfox Smart Building MOTION - Guide utilisateur / User guide version V1.0.1 2.1.5.01 Transmission périodique avec ou sans historique Le produit permet la mesure et la transmission périodique des valeurs des capteurs selon le schéma suivant : Le produit permet de relever à une certaine fréquence le nombre de détections de présence et le taux de luminosité dans la pièce, de stocker cette information et de l’envoyer par la suite périodiquement.
  • Page 20 Sigfox Smart Building MOTION - Guide utilisateur / User guide version V1.0.1 2.1.5.02 Transmission sur dépassement de seuil de la luminosité Le produit permet la détection de dépassement de seuil (haut et bas) pour le taux de luminosité selon le schéma suivant.
  • Page 21 Sigfox Smart Building MOTION - Guide utilisateur / User guide version V1.0.1 Explication des seuils et hystérésis : Les paramètres associés à ce mode de fonctionnement sont : • La période de transmission (égale à zéro dans ce cas d’usage) (registre 301).
  • Page 22: Transmission D'une Trame De Vie

    Sigfox Smart Building MOTION - Guide utilisateur / User guide version V1.0.1 2.1.6 Transmission d’une trame de vie Si le produit n’a pas de données périodiques configurées, et qu’aucun seuil n’est dépassé, il pourrait ne pas communiquer pendant une période longue.
  • Page 23: Fonctionnement Des Leds

    Sigfox Smart Building MOTION - Guide utilisateur / User guide version V1.0.1 NOTE: il est possible de programmer un envoi de trame uniquement après un certains nombre de détection de fronts (S381/ S383). Exemple : Produit en veille Codage Résultat...
  • Page 24: Configuration Du Produit

    Sigfox Smart Building MOTION - Guide utilisateur / User guide version V1.0.1 CONFIGURATION DU PRODUIT La configuration du produit au travers du port micro-USB peut désormais se faire de deux manières : via l’IoT Configurator (application à l’inter- face conviviale) soit par envoi de commandes AT. Pour ouvrir le boitier du produit se reporter au paragraphe 5.1.
  • Page 25: Mode Commande

    Sigfox Smart Building MOTION - Guide utilisateur / User guide version V1.0.1 3.2.2 Mode commande Utiliser un terminal port COM pour communiquer avec le produit. Nous utilisons le soft terminal port COM HERCULES disponible en téléchargement gratuit à l’adresse suivante : http://www.hw-group.com/products/hercules/index_en.html...
  • Page 26: Commande At

    Sigfox Smart Building MOTION - Guide utilisateur / User guide version V1.0.1 3.2.3 Commande AT Une commande débute avec les 2 caractères ASCII : « AT », suivis d’un ou plusieurs caractères et données (voir ci-après la syntaxe des com- mandes AT disponibles sur le modem).
  • Page 27: Description Des Registres

    Sigfox Smart Building MOTION - Guide utilisateur / User guide version V1.0.1 3.3. Description des registres A la mise sous tension le produit fonctionne selon la dernière configuration sauvegardée (configuration usine si c’est la première mise sous tension, ou si cette configuration n’a pas été changée).
  • Page 28 Sigfox Smart Building MOTION - Guide utilisateur / User guide version V1.0.1 Note concernant le registre S301 Attention : afin de laisser plus de libertés à l’utilisateur le produit n’a pas été bridé à un nombre maximum de sauvegardes par trame selon le réseau utilisé. Il est donc fortement recommandé de ne pas dépasser le nombre de relevés max autorisés par le réseau si l’on ne veut pas perdre de la donnée (les plus anciens relevés seront écrasés au profit des plus récents).
  • Page 29 Sigfox Smart Building MOTION - Guide utilisateur / User guide version V1.0.1 3.3.1.03 Registres configurant l’alarme pour le taux de luminosité Registre Taille Description Codage Détails (octets) S340 Type d’alarme choisi pour le taux de Décimal Défaut : 0 luminosité...
  • Page 30: Registres Réseau Sigfox

    Sigfox Smart Building MOTION - Guide utilisateur / User guide version V1.0.1 S382 Configuration du bornier (TOR2) Hexadécimal Défaut : 0x0 Min/max : <7:4> Période de garde 0: pas de période de garde 1: 10 ms 2: 20 ms 3: 50 ms...
  • Page 31: Description Des Trames

    Sigfox Smart Building MOTION - Guide utilisateur / User guide version V1.0.1 4. DESCRIPTION DES TRAMES 4.1. Trames montantes (uplink) Les trames montantes du produit vers le réseau (uplink) ont une taille variable selon les informations transmises. 4.1.1 Octets fixes Les deux premiers octets de la trame sont systématiquement dédiés pour indiquer le code de la trame et le statut comme présenté...
  • Page 32: Trame D'information Sur La Configuration Des Entrées Tor(S)

    Sigfox Smart Building MOTION - Guide utilisateur / User guide version V1.0.1 Description de la trame : Octets 2 et 3 : registre 300, période d’émission de la trame de vie Octets 4 et 5 : registre 301, période d’émission des données périodiques en nombre de sauvegarde à effectuer avant émission d’une trame Octets 6 et 7 : registre 320, période de sauvegarde : nombre de relevés (scrutations) à...
  • Page 33: Trame De Vie (Keep Alive)

    Sigfox Smart Building MOTION - Guide utilisateur / User guide version V1.0.1 4.1.5 Trame de vie (keep alive) Cette trame (0x30) est émise à la fréquence définie par le registre 300 uniquement si aucune donnée périodique n’est définie soit en mode alarme sur dépassement de seuil (S301=0).
  • Page 34: Trame De Données Périodique

    Sigfox Smart Building MOTION - Guide utilisateur / User guide version V1.0.1 4.1.8 Trame de données périodique Cette trame (0x4E) est envoyée selon la période choisie par l’utilisateur (période = S321xS320xS301) et contient les données périodiques comp- teur de présence et taux de luminosité relevés.
  • Page 35: Trame De L'alarme Tor

    Sigfox Smart Building MOTION - Guide utilisateur / User guide version V1.0.1 Dans l’exemple en gris cela donne : Octet 2 = 0x01, ce qui signifie que l’alarme est active Octet 3 = 0x18 soit 18 en décimal, au moment du déclenchement de l’alarme le taux de luminosité est donc à 18% 4.1.11...
  • Page 36: Trames Descendantes (Downlink)

    (RX window) pendant maximum 30 secondes, conformément au schéma ci-dessous : La configuration de la politique d’envoi de demande d’acquittement dans le produit adeunis® diffère selon que le produit est en mode pério- dique ou événementiel : •...
  • Page 37: Trame De Demande De La Configuration Du Produit

    Sigfox Smart Building MOTION - Guide utilisateur / User guide version V1.0.1 4.2.1 Trame de demande de la configuration du produit Cette trame permet de faire savoir au produit via le réseau qu’il doit émettre de nouveau la trame montante de configuration du produit (0x10).
  • Page 38: Installation Et Démarrage

    Sigfox Smart Building MOTION - Guide utilisateur / User guide version V1.0.1 5. Installation et démarrage Insérez un tournevis plat incliné vers la face avant du boitier dans l’ouverture sur le haut et 5.1. Ouvrir et fermer le boitier appuyez. Le boitier s’ouvre en deux et la face avant se détache.
  • Page 39: Changement De La Pile

    5.7) Exemple : Le produit Sigfox Smart Building MOTION peut aisément se coupler avec un contact porte câblé via le bornier (TOR2). Ainsi, positionné à côté de la porte d’un local sécurisé soumis à contrôle, le produit pourra envoyer une alarme à chaque ouverture/fermeture de porte et ainsi permettre au responsable sécurité...
  • Page 40: Fixation Du Produit

    Sigfox Smart Building MOTION - Guide utilisateur / User guide version V1.0.1 5.5. Positionnement correct du produit Position : dans la mesure du possible, installer l’émetteur à une hauteur minimale de 1m50 dans une zone non enclavée. Ne pas positionner le capteur face à une fenêtre ou au soleil.
  • Page 41: Historique Du Document

    Sigfox Smart Building MOTION - Guide utilisateur / User guide version V1.0.1 6. HISTORIQUE DU DOCUMENT Version Contenu V1.0.0 Création V1.0.1 Corrections et ajouts mineurs Page of 83 DISTRIBUTED BY TEXIM EUROPE...
  • Page 42: English

    Sigfox Smart Building MOTION - Guide utilisateur / User guide version V1.0.1 ENGLISH Page of 83 DISTRIBUTED BY TEXIM EUROPE...
  • Page 43: Products And Regulatory Information

    Version APP : V01.05.06 DISCLAIMER This document and the use of any information contained therein, is subject to the acceptance of the adeunis® terms and conditions. They can be downloaded from www.adeunis.com. adeunis® makes no warranties based on the accuracy or completeness of the contents of this document and reserves the right to make changes to specifi...
  • Page 44 Sigfox Smart Building MOTION - Guide utilisateur / User guide version V1.0.1 EU Declaration of Conformity Adeunis 283 rue LOUIS NEEL 38920 Crolles, France 04.76.92.01.62 www.adeunis.com Declare that the DoC is issued under our sole responsibility and belongs to the following product:...
  • Page 45 valid.
  • Page 46 Read the instructions in the manual. Risk of explosion if the battery is removed with an incorrect type. Contact Adeunis for more information if needed. The safety of this product is only guaranteed when it is used in accordance with its purpose. Maintenance should only be carried out by qualifi...
  • Page 47 Sigfox Smart Building MOTION - Guide utilisateur / User guide version V1.0.1 RECOMMANDATIONS REGARDING USE • Before using the system, check that the power supply voltage shown in the user manual corresponds to your supply. If it doesn’t, please consult your supplier.
  • Page 48: Device Overview

    1. DEVICE OVERVIEW Description: • The adeunis® Sigfox Smart Building MOTION device is a ready-to-use radio transmitter for detecting the presence of a heat source and determining the brightness level in a room. • This product meets the needs of users to monitor the presence and brightness of their buildings via an LPWAN network.
  • Page 49: Dimensions

    Sigfox Smart Building MOTION - Guide utilisateur / User guide version V1.0.1 1.2. Dimensions Values are in millimeters 1.3. Circuit board Internal antenna RF Module Sigfox Protocol Terminals USB port for device configuration Page of 83 DISTRIBUTED BY TEXIM EUROPE...
  • Page 50: Kare Platform Compatibility

    - 100 events on the digital input(s) The above values are estimates made under certain conditions of use and environment (25°C and 1 year of storage). They do not under any circumstances represent a commitment on the part of adeunis®. Page...
  • Page 51: Digital Input Interfaces

    Sigfox Smart Building MOTION - Guide utilisateur / User guide version V1.0.1 1.5.3 Digital input interfaces The schematic diagram of the digital input interfaces is as follows: Maximum absolute values Unit Minimum input voltage - 0,7 Maximum input voltage Electrical Characteristics...
  • Page 52: Device Operation

    This mode is used to configure the device registers. There are two ways to enter this mode: Open the adeunis® IoT Configurator application, connect a cable to the device’s micro-USB port and connect it to the computer or mobile phone.
  • Page 53: Three Transmission Modes To Meet Needs

    Sigfox Smart Building MOTION - Guide utilisateur / User guide version V1.0.1 2.1.5 Three transmission modes to meet needs The device can detect presence in a room, save this information and send it in three transmission modes. Periodic transmission Transmission over threshold...
  • Page 54 Sigfox Smart Building MOTION - Guide utilisateur / User guide version V1.0.1 Procedure to follow to program its registers according to the chosen mode. Which mode do I want my device in? Alarm on Periodic exceeding Periodic threshold Alarm What period do I want between each reading?
  • Page 55 Sigfox Smart Building MOTION - Guide utilisateur / User guide version V1.0.1 Example of possible configurations: Desired case (except 100% event) Associated Theoretical number configuration of periodic frames sent per day • Reading: 10 minutes • 321 = 300 •...
  • Page 56 Sigfox Smart Building MOTION - Guide utilisateur / User guide version V1.0.1 2.1.5.01 Periodic sending with or without history logs The device allows the measurement and the periodic sending of the sensor values according to the following diagram: The device makes it possible to record the temperature and the humidity at a certain frequency, to store this information and then to send it periodically.
  • Page 57 Sigfox Smart Building MOTION - Guide utilisateur / User guide version V1.0.1 2.1.5.02 Transmission over brightness threshold The device allows detection of exceeding threshold (high and low) for the brightness rate according to the following schema. The device sends a data frame when a threshold is exceeded but also when returning to normal.
  • Page 58 Sigfox Smart Building MOTION - Guide utilisateur / User guide version V1.0.1 Explanation of thresholds and hysteresis: The parameters associated with this operating mode are: • The transmission period (equal to zero in this use case) (register 301). • The acquisition period (register 321) •...
  • Page 59: Transmitting The Keep Alive Frame

    Sigfox Smart Building MOTION - Guide utilisateur / User guide version V1.0.1 2.1.6 Transmitting the Keep Alive frame If the device does not have periodic data configured, and no threshold is exceeded, it may not transmit data for a long time. So, to be sure that the device is working properly, it transmits a Keep Alive frame (0x30) according to a determined frequency (S300) The parameters associated with this operating mode is the setting of the transmission period of the Keep Alive frame (register 300).
  • Page 60: Operation Of The Leds

    Sigfox Smart Building MOTION - Guide utilisateur / User guide version V1.0.1 NOTE: It is possible to program the sending of a frame only after a certain number of edge detections (S381/S383). Product in standby Register Value code Value Result...
  • Page 61: Device Configuration

    Sigfox Smart Building MOTION - Guide utilisateur / User guide version V1.0.1 DEVICE CONFIGURATION The device configuration using the micro-USB port can now be done in two ways: using the IoT Configurator (application on the user-friendly interface) or by transmitting AT commands. To open the device casing, refer to section 5.1.
  • Page 62: Command Mode

    Sigfox Smart Building MOTION - Guide utilisateur / User guide version V1.0.1 3.2.2 Command mode Use a COM port terminal block to communicate with the device. We use the HERCULES COM port soft terminal available to download for free by clicking the following link: http://www.hw-group.com/products/hercules/index_en.html...
  • Page 63: At Command

    Sigfox Smart Building MOTION - Guide utilisateur / User guide version V1.0.1 3.2.3 AT Command A command starts with the 2 ASCII characters: «AT», followed by one or more characters and data (see the list below for the syntax of the AT commands available on the modem).
  • Page 64: Description Of The Registers

    Sigfox Smart Building MOTION - Guide utilisateur / User guide version V1.0.1 3.3. Description of the registers On start up the device operates according to the last saved configuration (Factory Configuration if it is the first start up, or if this configuration has not been changed).
  • Page 65 Sigfox Smart Building MOTION - Guide utilisateur / User guide version V1.0.1 3.3.1.03 Registers that configure the presence alarm Register Size Description Encoding Details (bytes) S322 Inhibition time of the Decimal Default: 1 presence detector Min/max: 1 to 65535 Unit: x 10 seconds...
  • Page 66 Sigfox Smart Building MOTION - Guide utilisateur / User guide version V1.0.1 3.3.1.05 Registers that configure digital input alarm(s) Register Size Description Encoding Details (bytes) S380 Configuration of the button (Digital Hexadecimal Default: 0x41 Input 1) Min/max: <7:4> Debounce time 0: No debounce time...
  • Page 67: Sigfox Network Registers

    Sigfox Smart Building MOTION - Guide utilisateur / User guide version V1.0.1 S390 Event counter for the button (Digi- Decimal Default: 0 tal Input1) Min/max: 0– 4294967295 Value reset to 0 with a Power-On reset S391 Event counter for the button (Digi-...
  • Page 68: Description Of Frames

    Sigfox Smart Building MOTION - Guide utilisateur / User guide version V1.0.1 4. DESCRIPTION OF FRAMES 4.1. Uplink frames The uplink frames of the device to the network have a variable size according to the information transmitted. 4.1.1 Fixed bytes...
  • Page 69: Information Frame On Configuration Of Digital Input(S)

    Sigfox Smart Building MOTION - Guide utilisateur / User guide version V1.0.1 Description of the frame: Bytes 2 and 3: register 300, transmission period of the Keep Alive frame Bytes 4 and 5: register 301, period of transmission of the periodic data in number of backups (history logs) to be carried out before trans- mission of a frame Bytes 6 and 7: register 320, backup period: number of readings to be made before making a backup (history logs).
  • Page 70: Keep Alive

    Sigfox Smart Building MOTION - Guide utilisateur / User guide version V1.0.1 4.1.5 Keep alive This frame (0x30) is transmitted at the frequency defined by the register 300 only if no periodic data is defined or in alarm mode on a threshold overflow (S301 = 0).
  • Page 71: Periodic Data Frame

    Sigfox Smart Building MOTION - Guide utilisateur / User guide version V1.0.1 4.1.8 Periodic data frame This frame (0x4E) is sent according to the period chosen by the user (period = S321xS320xS301) and contains the periodic presence count and brightness rate readings.
  • Page 72: Digital Input Alarm Frame

    Sigfox Smart Building MOTION - Guide utilisateur / User guide version V1.0.1 In the example in grey, this results in: Byte 2 = 0x01, which means the alarm is active Byte 3 = 0x18 i.e. 24 in decimal, the brightness rate is therefore 24% when the alarm is triggered.
  • Page 73: Downlink Frames

    (RX window) for a maximum of 30 seconds, in accordance with the diagram below: The configuration of the sending policy of the acknowledgment request in the adeunis® product differs according to whether the product is in periodic or event mode: •...
  • Page 74: Product Configuration Request Frame

    Sigfox Smart Building MOTION - Guide utilisateur / User guide version V1.0.1 4.2.1 Product configuration request frame This frame allows to inform the product via the network that it must resend the product configuration uplink frame (0x10). Code PAYLOAD 0x01 4.2.2 Network configuration request frame...
  • Page 75: Installation And Start-Up

    Sigfox Smart Building MOTION - Guide utilisateur / User guide version V1.0.1 5. Installation and Start-up 5.1. Opening and closing the unit Insert a flat screwdriver into the opening on the top of the casing and press. The casing opens in two and the front panel comes off.
  • Page 76: Replacing The Battery

    Sigfox Smart Building MOTION - Guide utilisateur / User guide version V1.0.1 5.3. Replacing the battery When the low battery indicator is enabled (indicator in the frame or flashing of the red LED), it is possible to change the internal battery of the unit.
  • Page 77: Correct Positioning Of The Device

    Sigfox Smart Building MOTION - Guide utilisateur / User guide version V1.0.1 5.5. Correct positioning of the device Position: To the extent possible, install the transmitter at a min- imum height of 1.50 m in a non-enclosed area. Do not position the sensor in front of a window or in the sun.
  • Page 78: Document Versions

    Sigfox Smart Building MOTION - Guide utilisateur / User guide version V1.0.1 6. DOCUMENT VERSIONS Version Content V1.0.0 Creation V1.0.1 Corrections and minor add-ons Page of 83 DISTRIBUTED BY TEXIM EUROPE...
  • Page 79 Sigfox Smart Building MOTION - Guide utilisateur / User guide version V1.0.1 DEUTSCH Vor- schriften Page of 83 DISTRIBUTED BY TEXIM EUROPE...
  • Page 80 Recht vor, jederzeit und ohne Vorankündigung Änderungen an den Produktspezifi kationen und -beschreibungen vorzunehmen. adeunis® behält sich alle Rechte an diesem Dokument und den darin enthaltenen Informationen vor. Die Ver- vielfältigung, Nutzung oder Weiterverbreitung an Dritte ohne ausdrückliche Genehmigung ist streng untersagt.
  • Page 81 Programmiersprachen, unter Verwendung jeglicher elektrischer, mechanischer, magnetischer, optischer, manueller Geräte oder anderer Methoden, ist untersagt. adeunis® behält sich das Recht vor, ohne schriftliche Bekanntgabe und ohne ausdrückliches Verlangen seiner Kun- den die technischen Spezifi kationen oder Funktionen seiner Produkte zu ändern und sicherzustellen, dass die ihnen zur Verfügung gestellten Informationen gültig sind.
  • Page 82 Sigfox Smart Building MOTION - Guide utilisateur / User guide version V1.0.1 UMWELTSCHUTZHINWEISE Es wurden alle überfl üssigen Verpackungsmaterialien vermieden. Wir haben uns bemüht, dass die Verpackung UMWELTSCHUTZHINWEISE leicht in drei Materialarten getrennt werden kann: Pappe (Schachtel), expandiertes Polystyrol (Puff ermaterial) und Polyethylen (Tüten, Schaumstoff...
  • Page 83 Sigfox Smart Building MOTION - Guide utilisateur / User guide version V1.0.1 GEBRAUCHSHINWEISE • Überprüfen Sie vor Benutzung des Systems, ob die in dessen Betriebsanleitung angegebene Versorgungsspan- nung mit Ihrer Stromquelle übereinstimmt. Falls nicht, wenden Sie sich an Ihren Lieferanten.
  • Page 84 Contact details The Netherlands Belgium UK & Ireland Elektrostraat 17 Zuiderlaan 14 bus 10 St. Mary’s House, Church Lane NL-7483 PG Haaksbergen B-1731 Zellik Carlton Le Moorland Lincoln LN5 9HS +31 (0)53 573 33 33 +32 (0)2 462 01 00 +44 (0)1522 789 555 F: +31 (0)53 573 33 30 +32 (0)2 462 01 25...

Table des Matières