2.2. Application operation

2.2.1 Periodic transmission

The product allows the measurement and the periodic transmission of the values of the sensors according to the following diagram:
FR
EN
The settings associated with this mode of operation are:
the transmission period (register 301).
the presence and type of external sensor (registers 320 and 322).
A complete list of the registers can be found in paragraph 3.4.
Eg:
Register
S301
S320
S322
Product in standby
reached?
Measurement input A
(if enabled)
Measurement input B
(if enabled)
Send frame 0x42
Value encoding
Decimal
Hexadecimal
Hexadecimal
No
Period
YES
Value
6
0x02
0x01
Result
Periodic mode with a period of
6x10min = 60 minutes
Channel A configured for a sen-
sor 4-20mA
Channel B configured for a
sensor 0-10V