Repli Mode; Application Operation; Periodic Transmission - ADEUNIS Sigfox RC1 ANALOG Guide Utilisateur

Masquer les pouces Voir aussi pour Sigfox RC1 ANALOG:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

sigfox RC1 ANALOG - Guide utilisateur / User guide version V2.0.1
2.1.4

REPLI mode

The product enters this very low consumption mode following the detection of a level of battery that is too low. In
this mode the product wakes up every 5 seconds to make the red LED flash twice.
The replacement of the battery (if the product is a replaceable battery version) followed by the application of the
magnet takes the product out of this mode to return it to the operating mode.

2.2. Application operation

FR
2.2.1

Periodic transmission

The product allows the measurement and the periodic transmission of the values of the sensors according to the
following diagram:
EN
The settings associated with this mode of operation are:
the transmission period (register 301).
the presence and type of external sensor (registers 320 and 322).
A complete list of the registers can be found in paragraph 3.4.
Eg:
Registre
S301
S320
S322
Product in standby
reached?
Measurement input A
(if enabled)
Measurement input B
(if enabled)
Send frame 0x40
Value encoding
Decimal
Hexadecimal
Hexadecimal
No
Period
YES
Value
6
0x02
0x01
Result
Periodic mode with a
period of 6x10min = 60
minutes
Channel A configured for a
sensor 4-20mA
Channel B configured for a
sensor 0-10V