Test Mode; Operation Of The Leds - ADEUNIS Sigfox RC1 ANALOG Guide Utilisateur

Masquer les pouces Voir aussi pour Sigfox RC1 ANALOG:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

sigfox RC1 ANALOG - Guide utilisateur / User guide version V2.0.1
2.2.5

TEST Mode

This mode allows the user to perform tests of the product more quickly by reducing the time scales of the produc-
tion mode and modifying the behavior of the LEDs.
It is obtained by positioning register S306 at the value 2 in the COMMAND mode. Once out of the command
mode, the product returns to the previously defined application behavior but with the following changes:
- register S300: the periodicity of the Keep Alive frame is expressed in groups of twenty seconds instead
of tens of minutes. Hence in test mode when register 300 = 144, the Keep Alive frame is no longer sent every
144x10min=1440 minutes or 24h but every 144x20s=2880 seconds or 48 minutes.
- register S301: the periodicity of the sending of data (periodic mode) is expressed in groups of twenty
seconds instead of tens of minutes. Hence in test mode when register 301 = 1, the data frame is no longer sent
every 10min but every 20 seconds.
- In the event mode with transmission on threshold overrun the monitoring period of inspection by the
sensors, normally 10 minutes is now, in TEST mode, set to 100 seconds.
-The LEDS also have different behavior, allowing a visual feedback to the user in the event of transmission
and reception of frames (see paragraph 2.3 for more details).
A complete list of the registers can be found in paragraph 3.4.
E.g.:
Register
S306
S300
S301

2.3. Operation of the LEDs

Mode
Transmission of frame (TEST mode
only)
Reception of frame (TEST mode
only)
Product in Park mode
Magnet detection process (1 to 6
seconds)
Product start (after detection of
the magnet)
Switching to the Command mode
Battery level low
Product faulty (return to factory)
Product in production mode (TEST
mode only)
Product in REPLI mode
Value encoding
Decimal
Decimal
Decimal
LED red state
ON during the reception of a
downlink frame
OFF
OFF
OFF
Continuously lit
Flashing (0.5s ON every 60s)
Fixed ON
50ms ON / 30 s OFF
Flashing (100ms ON / 100ms OFF) x
2 every 5s
Value
Result
2
The product is in TEST mode
72
The Keep Alive frame is sent every:
72x20=1440s = 24 minutes
6
Periodic mode with a period of 6x20 =
120s = 2 minutes
LED green state
ON during the transmission cycle
OFF
ON from detection of the magnet
up to a maximum of 1 second
Rapid flashing 6 cycles, 100 ms ON
/ 100 ms OFF
Continuously lit
50ms ON / 30 s OFF (just before
the red LED)
FR
EN
Page
61
of 86

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Arf8191aaArf8191ba

Table des Matières