WMBUS ANALOG PWR - Guide utilisateur / User guide version V2.0.0

2.2.5 TEST Mode

This mode allows the user to perform tests of the product more quickly by reducing the time scales of the production mode and modifying the
behaviour of the LEDs.
It is obtained by positioning register S306 at the value 2 in the COMMAND mode. Once out of the command mode, the product returns to the
previously defined application behaviour but with the following changes:
- register S300: the periodicity of the Keep Alive frame is expressed in groups of twenty seconds instead of tens of minutes. Hence in
test mode when register 300 = 144, the Keep Alive frame is no longer sent every 144x10min=1440 minutes or 24h but every 144x20s=2880
seconds or 48 minutes.
- register S301: the periodicity of the sending of data (periodic mode) is expressed in groups of twenty seconds instead of tens of
minutes. Hence in test mode when register 301 = 1, the data frame is no longer sent every 10min but every 20 seconds.
- In the event mode with transmission on threshold overrun the monitoring period of inspection by the sensors, normally 10 minutes
is now, in TEST mode, set to 100 seconds.
-The LEDS also have different behaviour, allowing a visual feedback to the user in the event of transmission and reception of frames
(see paragraph 2.3 for more details).
A complete list of the registers can be found in paragraph 3.4.
E.g.:
Register
S306
S300
S301

2.3. Operation of the LEDs

Mode
Transmission of frame (TEST mode only)
Reception of frame (TEST mode only)
Product in Park mode
Magnet detection process (1 to 6 seconds)
Product start (after detection of the magnet) OFF
Switching to the Command mode
Battery level low
Product faulty (return to factory)
Product in production mode (TEST mode
only)
Product in REPLI mode
Value encoding
Decimal
Decimal
Decimal
LED red state
ON during the reception of a downlink frame
OFF
OFF
Continuously lit
Flashing (0.5s ON every 60s)
Fixed ON
50ms ON / 50 s OFF
Flashing (100ms ON / 100ms OFF) x 2 every 5s
Value
Result
2
The product is in TEST mode
72
The Keep Alive frame is sent every: 72x20=1440s
= 24 minutes
6
Periodic mode with a period of 6x20 = 120s = 2
minutes
LED green state
ON during the transmission cycle
OFF
ON from detection of the magnet up to a
maximum of 1 second
Rapid flashing 6 cycles, 100 ms ON / 100
ms OFF
Continuously lit
50ms ON / 50 s OFF (just before the red
LED)
FR