Repli Mode; Application Operation; Periodic Transmission - ADEUNIS sigfox RC1 Pulse Guide Utilisateur

Masquer les pouces Voir aussi pour sigfox RC1 Pulse:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

sigfox RC1 Pulse - Guide utilisateur / User guide version V2.0.2

2.1.4 REPLI mode

The product enters this very low consumption mode following the detection of a level of battery that is too low. In this mode the product wakes
up every 5 seconds to make the red LED flash twice.
The replacement of the battery (if the product is a replaceable battery version) followed by the application of the magnet takes the product out
of this mode to return it to the operating mode.
2.2.

Application operation

2.2.1 Periodic transmission

The product allows the measurement and the periodic transmission of the values of the sensors according to the following diagram:
EN
The settings associated with this mode of operation are:
Transmission period (register 301)
Enabling and Configuring inputs (register 320)
Anti-bounce timer period (registers S322)
A complete list of the registers can be found in paragraph 3.4.
Eg:
Register
Value encoding
S301
Decimal
S320
Hexadecimal
S322
Hexadecimal
Product in standby
No
Period
reached?
Yes
Send frame 0x46
Value
6
0x39
0x57
Detected
No
and valida-
ted pulse
?
Yes
Counting
of the impulse
Result
Periodic mode with a period of 6x10min = 60 minutes
Channel A :
Activated
Meter other than gas
Tamper input activated
Channel B :
Activated
Gas meter
Tamper input disabled
Anti-rebound :
Channel A = 500ms
Channel B = 100ms
Page
66
of 104

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Sigfox rc1 pulse atexArf8230caArf8230ga