sigfox RC1 Pulse - Guide utilisateur / User guide version V2.0.2
4.2.2 Network configuration request frame
This frame allows to inform the product via the network that it must resend the network configuration uplink frame (0x20).
0
1
Code
PAYLOAD
0x02
X
4.2.3 Frame for adding an offset to pulse counters
These frames (0x03 and 0x04) allows to add an offset to the counter value on each channel.
0
1 to 4
Code
0x03
Offset - A-channel
0x03
0x00000015
Its size is of 5 bytes.
Description of the frame :
•
Bytes 1 to 4: Offset - channel A : numbers of pulses to add to current index of the meter (channel A) (unsigned 32-bits, MSB first).
In the example in grey this gives:
•
Bytes 1 to 4 =0x00000015 so 21 pulses to add to channel A counter
0
Code
0x04
Offset - B-channel
0x04
0x00000050
Its size is of 5 bytes.
Description of the frame :
• Bytes 1 to 4: Offset - channel B : numbers of pulses to add to current index of the meter (channel B) (unsigned 32-bits, MSB first).
In the example in grey this gives:
• Bytes 1 to 4 = 0x00000050 so 80 pulses to add to channel B counter
4.2.4 Specific register value request frame
This frame (0x40) allows to inform the product via the network that it must send the values of specific registers.
Frame 0x40 :
0
1
Code
PAYLOAD
0x40
CONF ID1
Description of the frame:
•
Bytes 1 to N : CONF IDX (8bits): index of the register to be sent.
The corresponding register is 300 + CONF IDX value.
For example, if CONF ID1 = 20, the product will send back the value of register number 320.
The associated uplink frame has the code 0x31 (see paragraph 4.1.5).
2
3
X
X
1 to 4
2
3
CONF ID2
CONF ID3
4
5
X
X
4
5
X
X
6
7
X
X
EN
...
7
X
CONF IDn
Page
91