Description of the frame :
Byte 2: frame index: index of this frame in a multi-message sequence
Bytes 3 to 4 : Delta A2 : index variation of channel A during the time interval between 3 to 4 hours after transmitting the previous frame.
Bytes 5 to 6 : Delta B2 : index variation of channel B during the time interval between 3 to 4 hours after transmitting the previous frame.
...
In the example in grey this gives:
Byte 2: frame index: index of this frame in a multi-message sequence (always null in this configuration) = 2 (third frame)
Bytes 3 to 4 : Delta A2 : index variation of channel A during the time interval between 3 to 4 hours after transmitting the previous frame =
0x0100 so 256 additional pulses
Bytes 5 to 6 : Delta B2 : index variation of channel B during the time interval between 3 to 4 hours after transmitting the previous frame =
0x00F0 so 240 additional pulses
...
The other frames (4 to 13) are on the same model, the interpretation is the same as before:
EN
0
Code
0x48
0x48
0
Code
0x48
0x48
0
Code
0x48
0x48
0
Code
0x48
0x48
0
Code
0x48
0x48
0
Code
0x48
0x48
0
Code
0x48
0x48
1
2
Status
Cf Status
Frame index
0xA3
0x03
1
2
Status
Cf Status
Frame index
0xA3
0x04
1
2
Status
Cf Status
Frame index
0xA3
0x05
1
2
Status
Cf Status
Frame index
0xA3
0x06
1
2
Status
Cf Status
Frame index
0xA3
0x07
1
2
Status
Cf Status
Frame index
0xA3
0x08
1
2
Status
Cf Status
Frame index
0xA3
0x09
3 to 4
5 to 6
PAYLOAD
Delta A4
Delta B4
0x074A
0x003B
3 to 4
5 to 6
PAYLOAD
Delta A6
Delta B6
0x0100
0x000F
3 to 4
5 to 6
PAYLOAD
Delta A8
Delta B8
0x00A5
0x0000
3 to 4
5 to 6
PAYLOAD
Delta A10
Delta B10
0x0012
0x0020
3 to 4
5 to 6
PAYLOAD
Delta A12
Delta B12
0x0100
0x00F0
3 to 4
5 to 6
PAYLOAD
Delta A14
Delta B14
0x074A
0x003B
3 to 4
5 to 6
PAYLOAD
Delta A16
Delta B16
0x0100
0x000F
7 to 8
9 to 10
Delta A5
Delta B5
0x0010
0x0021
7 to 8
9 to 10
Delta A7
Delta B7
0x0000
0x00F1
7 to 8
9 to 10
Delta A9
Delta B9
0x0005
0x00B5
7 to 8
9 to 10
Delta A11
Delta B11
0x0007
0x0010
7 to 8
9 to 10
Delta A13
Delta B13
0x0000
0x0015
7 to 8
9 to 10
Delta A15
Delta B15
0x0010
0x0021
7 to 8
9 to 10
Delta A17
Delta B17
0x0000
0x00F1
Page