ADEUNIS sigfox RC1 Pulse Guide Utilisateur page 79

Masquer les pouces Voir aussi pour sigfox RC1 Pulse:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

sigfox RC1 Pulse - Guide utilisateur / User guide version V2.0.2
S323
4
Current value of meter -
channel A
S324
4
Current value of meter -
channel B
S325
2
Flow calculation period
(channels A and B)
S326
2
Flow threshold (channel A)
S327
2
Flow threshold (channel B)
S328
2
Leak threshold (channel A)
S329
2
Leak threshold (channel B)
S330
2
Number of daily periods
under the leak threshold
(channel A)
S331
2
Number of daily periods
under the leak threshold
(channel B)
S332
1
Scan period for Channel A
tamper input
S333
1
Tamper detection threshold
channel A
S334
1
Scan period for Channel B
tamper input
S335
1
Tamper detection threshold
channel B
Decimal
Default value: 0
Min/max : 0 to (2
Unit : number of pulses
In COMMAND mode, it is possible to write a new value in this
register (for example an initialization value, an adjustment
value ...).
Decimal
Default value: 0
Min/max : 0 to (2
Unit : number of pulses
In COMMAND mode, it is possible to write a new value in this
register (for example an initialization value, an adjustment
value ...).
Decimal
Default value: 60
Min/max : 1 to 1440
Unit :
x 1min if S306=1
x 20s if S306=2
Decimal
Default value :0 (deactivated)
Min/max : 0 to 65535
Unit: pulses per hour
Decimal
Default value :0 (deactivated)
Min/max : 0 to 65535
Unit: pulses per hour
Decimal
Default value: 0
Min/max : 0 to 65535
Unit : pulses per hour
Decimal
Default value: 0
Min/max : 0 to 65535
Unit : pulses per hour
Decimal
Default value: 0 (deactivated)
Min/max : 0 to 1440
Unit : none
The multiplication of this register by the period of flow mea-
surement must be less than 24 hours otherwise the product
will be perpetually in alarm.
Decimal
Default value: 0 (deactivated)
Min/max : 0 to 1440
Unit : none
The multiplication of this register by the period of flow mea-
surement must be less than 24 hours otherwise the product
will be perpetually in alarm.
Decimal
Default: 2
Min/Max: 1 to 255
Unit: x10 seconds
Decimal
Default: 3
Min/Max: 1 to 255
Unit: none
Number of positive scans of A-channel tamper before trigger-
ing the tamper alarm
Decimal
Default: 2
Min/Max: 1 to 255
Unit: x10 seconds
Decimal
Default: 3
Min/Max: 1 to 255
Unit: none
Number of positive scans of B-channel tamper before trigger-
ing the tamper alarm
)
32-1
)
32-1
EN
Page
79
of 104

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Sigfox rc1 pulse atexArf8230caArf8230ga

Table des Matières