4.1.2 Frames of information on the product configuration

Following reception of a downlink frame with the code 0x01 or on switching to the operating mode (from the Park or Command Mode), the
following frames (0x10, 0x11 et 0x12) representing the application configuration of the product are transmitted:
0
1
Code
Status
0x10
Cf Status
0x10
0xA3
Description of the frame:
Byte 2 : register 306, product mode (Park, Standard (production), Test or REPLI)
Byte 3 : register 301, periodicity of transmission (periodic mode), expressed in minutes
EN
Byte 4 : register 320, channels configuration (A and B)
Byte 5 : register 321, history configuration (channels A and B)
Byte 6 : register 322, anti-bounce filter period (channels A and B)
Bytes 7 and 8 : register 325, flow calculation period (x1 minute if S306=1, x20 seconds if S306=2)
In the example in grey this gives:
Byte 2 : S306=0x01: PRODUCTION mode in progress
Byte 3 : S301=0x06 = 60 (decimal): transmission period is set to 60 minutes.
Byte 4 : S320 = 0x39 : channels configuration (A and B) :
Channel A :
- Activated
- Meter other than gas
- Tamper input activated
Channel B :
- Activated
- Gas meter
- Tamper input deactivated
Byte 5 : S321=0x02, history configuration: channels A and B : history mode with recording of counters every hours and sending every 24h
so 24 values by meter
Byte 6 : S322=0x57, anti-bounce channel A = 500ms and channel B = 100ms
Bytes 7 and 8 : register 325=0x003C=60 (decimal), flow calculation period is set to 60min
0
Code
0x11
Cf Status
0x11
Description of the frame:
Bytes 2 and 3 : register 326, flow threshold (channel A)
Bytes 4 and 5 : register 327, flow threshold (channel B)
Bytes 6 and 7 : register 328, leak threshold (channel A)
Bytes 8 and 9 : register 329, leak threshold (channel B)
In the example in grey this gives:
Bytes 2 and 3 : S326=0x2710=10 000 (decimal), flow threshold for channel A is to 10,000 pulses per hour
Bytes 4 and 5 : S327=0x7530=30 000 (decimal), flow threshold for channel B is to 30,000 pulses per hour
Bytes 6 and 7 : S328=0x000A=10 (decimal), leak threshold for channel A is to 10 pulses per hour
Bytes 8 and 9 : S329=0x0000, leak threshold for channel B is to 0 pulse per hour
0
Code
Status
0x12
Cf Status
0x12
0xA3
2
3
S306
S301
0x01
0x06
1
2 - 3
Status
S326
0xA3
0x2710
1
2 - 3
PAYLOAD
S330
0x0003
4
5
PAYLOAD...
S320
S321
0x39
0x02
4 - 5
6 - 7
PAYLOAD
S327
S328
0x7530
0x000A
4 - 5
S331
0x0005
6
7 - 8
S322
S325
0x57
0x003C
8 - 9
S329
0x0000