4.1.2 Frames of information on the product configuration

Following reception of a downlink frame with the code 0x01 or on switching to the operating mode (from the Park or Command Mode), the
following frames (0x10, 0x11 et 0x12) representing the application configuration of the product are transmitted:
0
1
Code
Status
0x10
Cf Status
0x10
0xA3
Description of the frame:
Byte 2 : register 306, product mode (Park, Standard (production), Test or REPLI)
Bytes 3 to 4 : register 301, periodicity of transmission (periodic mode), expressed in minutes
Byte 5 : register 320, channels configuration (A and B)
Byte 6 : register 321, history configuration (channels A and B)
Byte 7 : register 322, anti-bounce filter period (channels A and B)
Bytes 8 and 9 : register 325, flow calculation period (x1 minute if S306=1, x20 secondes if S306=2)
In the example in grey this gives:
Byte 2 : S306=0x01: PRODUCTION mode in porgress
Bytes 3 et 4 : S301=0x003C = 60 (decimal): transmission period is set to 60 minutes.
Byte 5 : S320 = 0x39 : channels configuration (A and B) :
Channel A :
- Activated
- Meter other than gas
- Tamper input activated
Channel B :
- Activated
- Gas meter
- Tamper input deactivated
Byte 6 : S321=0x02, history configuration: channels A and B : history mode with recording of counters every hours and sending every 24h
so 24 values by meter
Byte 7 : S322=0x57, anti-bounce channel A = 500ms and channel B = 100ms
Bytes 8 and 9 : register 325=0x003C=60 (decimal), flow calculation period is set to 60min
0
1
Code
Status
0x11
Cf Status
0x11
0xA3
Description of the frame:
Bytes 2 and 3 : register 326, flow threshold (channel A)
Bytes 4 and 5 : register 327, flow threshold (channel B)
Bytes 6 and 7 : register 328, leak threshold (channel A)
Bytes 8 and 9 : register 329, leak threshold (channel B)
In the example in grey this gives:
Bytes 2 and 3 : S326=0x2710=10 000 (decimal), flow threshold for channel A is to 10,000 pulses per hour
Bytes 4 and 5 : S327=0x7530=30 000 (decimal), flow threshold for channel B is to 30,000 pulses per hour
Bytes 6 and 7 : S328=0x000A=10 (decimal), leak threshold for channel A is to 10 pulses per hour
Bytes 8 and 9 : S329=0x0000, leak threshold for channel B is to 0 pulse per hour
2
3 - 4
5
S306
S301
S320
0x01
0x0006
0x39
2 - 3
4 - 5
S326
S327
0x2710
0x7530
6
7
PAYLOAD...
S321
S322
0x02
0x57
6 - 7
8 - 9
PAYLOAD
S328
S329
0x000A
0x0000
8 - 9
S325
0x003C