ADEUNIS sigfox RC4 Pulse Guide Utilisateur page 76

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

sigfox RC4 Pulse - Guide utilisateur / User guide version V1.0.0
323
4
324
4
FR
325
2
EN
326
2
327
2
328
2
329
2
330
2
331
2
332
1
333
1
334
1
335
1
Current value of meter -
channel A
Current value of meter -
channel B
Flow calculation period
(channels A and B)
Flow threshold (channel A)
Flow threshold (channel B)
Leak threshold (channel A)
Leak threshold (channel B)
Number of daily periods
under the leak threshold
(channel A)
Number of daily periods
under the leak threshold
(channel B)
Scan period for Channel A
tamper input
Tamper detection threshold
channel A
Scan period for Channel B
tamper input
Tamper detection threshold
channel B
Decimal
Default value: 0
Min/max : 0 to (2
Unit : number of pulses
In COMMAND mode, it is possible to write a new value in this
register (for example an initialization value, an adjustment
value ...).
Decimal
Default value: 0
Min/max : 0 to (2
Unit : number of pulses
In COMMAND mode, it is possible to write a new value in this
register (for example an initialization value, an adjustment
value ...).
Decimal
Default value: 60
Min/max : 1 to 1440
Unit :
x 1min if S306=1
x 20s if S306=2
Decimal
Default value :0 (deactivated)
Min/max : 0 to 65535
Unit: pulses per hour
Decimal
Default value :0 (deactivated)
Min/max : 0 to 65535
Unit: pulses per hour
Decimal
Default value: 0
Min/max : 0 to 65535
Unit : pulses per hour
Decimal
Default value: 0
Min/max : 0 to 65535
Unit : pulses per hour
Decimal
Default value: 0 (deactivated)
Min/max : 0 to 1440
Unit : none
The multiplication of this register by the period of flow measu-
rement must be less than 24 hours otherwise the product will
be perpetually in alarm.
Decimal
Default value: 0 (deactivated)
Min/max : 0 to 1440
Unit : none
The multiplication of this register by the period of flow measu-
rement must be less than 24 hours otherwise the product will
be perpetually in alarm.
Decimal
Default: 2
Min/Max: 1 to 255
Unit: x10 seconds
Decimal
Default: 3
Min/Max: 1 to 255
Unit: none
Number of positive scans of A-channel tamper before trigge-
ring the tamper alarm
Decimal
Default: 2
Min/Max: 1 to 255
Unit: x10 seconds
Decimal
Default: 3
Min/Max: 1 to 255
Unit: none
Number of positive scans of B-channel tamper before trigge-
ring the tamper alarm
32-1
)
)
32-1
Page
76
of 101