Network Configuration Request Frame; Frame For Adding An Offset To Pulse Counters; Specific Register Value Request Frame - ADEUNIS sigfox Pulse 868 Guide Utilisateur

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

sigfox Pulse - Guide utilisateur / User guide version V2.0.0

4.2.2 Network configuration request frame

This frame allows to inform the product via the network that it must resend the network configuration uplink frame (0x20).
0
1
Code
PAYLOAD
0x02
X

4.2.3 Frame for adding an offset to pulse counters

These frames (0x03 and 0x04) allows to add an offset to the counter value on each channel.
0
1 to 4
Code
0x03
Offset - A-channel
0x03
0x00000015
Its size is of 5 bytes.
Description of the frame :
Bytes 1 to 4: Offset - channel A : numbers of pulses to add to current index of the meter (channel A) (unsigned 32-bits, MSB first).
In the example in grey this gives:
Bytes 1 to 4 =0x00000015 so 21 pulses to add to channel A counter
0
Code
0x04
Offset - B-channel
0x04
0x00000050
Its size is of 5 bytes.
Description of the frame :
• Bytes 1 to 4: Offset - channel B : numbers of pulses to add to current index of the meter (channel B) (unsigned 32-bits, MSB first).
In the example in grey this gives:
• Bytes 1 to 4 = 0x00000050 so 80 pulses to add to channel B counter

4.2.4 Specific register value request frame

This frame (0x40) allows to inform the product via the network that it must send the values of specific registers.
Frame 0x40 :
0
1
Code
PAYLOAD
0x40
CONFID1
2
3
X
X
1 to 4
2
3
CONFID2
CONFID3
4
5
X
X
4
5
X
X
6
7
FR
X
X
EN
...
7
X
CONFIDn
Page
87
of 100

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Arf8230caArf8230ga

Table des Matières