Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

sigfox Pulse - Guide utilisateur / User guide version V2.0.0

3.3. AT commands

A command starts with 2 ASCII characters: "AT", followed by one or more characters and data (see the list below for the syntax of AT com-
mands available on the modem).
Each command must finish with a "CR" or "CR" "LF" – both are acceptable.
(CR indicates: Carriage Return, LF indicates: Line Feed)
Once the command has been received, the modem will feedback:
FR
<cr><lf> "Data" for ATS type playback control <n> ?, AT/S or AT/V
"O" <cr><lf>, for any other command when this has been accepted.
"E" <cr><lf>, if it refuses the command due to a syntax error, unknown command, unknown range, invalid parameter, etc.
"CM" <cr><lf>, if it accepts the input in command mode
Table of AT commands:
EN
Command
+++
ATPIN <PIN>
AT/V
AT/N
ATS<n>?
AT/S
ATS<n>=<m>
AT&W
ATO
ATT63 PROVIDER
Example of a set of commands and corresponding responses that can be seen on the terminal:
Syntax
of the order
+++
ATS202=1
ATT63 PROVIDER
ATS202=1
ATS202?
AT&W
ATO
Interpreting the previous example: the user wanted to modify the number of repetition after having made an unauthorised command (answer
E), and the ranges were unblocked in order to modify the range. The range S202 was verified and the parameters were saved before exiting.
When exiting command mode, the device will start a new cycle of emission.
Description
Input request in command mode
Gives access to AT commands if register S304 is different of 0
Feeds back the version of the APPLICATIF and RTU software
Feeds back the type of network
Feeds back the content of the n range
Edits the content of all of the user ranges in the form of a list. /
Transfers the m value to the n range
Saves the current configuration to non-volatile memory.
Exit command mode
Unblock the operating range
Description
Input request in command mode
Changing the number of repetitions
Unblock the operating range
Changing the number of repetitions
Feeds back the value of the S202 range
Memory request for the state range
Output request in command mode
Reply example
CONNECTING... <cr><lf>
CM<cr><lf>
APP_8230EAA_PRG1706_V01.02.02:RTU_RTU_
WMBUS_868_PRG_1601_V00.00.03
Ou selon la version du réseau
APP_8181AAA_PRG1701_
V01.00.02:RTU_8120AAB_PRG_1701_V01.00.01
"LoRa" ou "SIGFOX" or « WMBUS »
S<n>=<y><cr><lf> with <y> as the register
content
«O»<cr><lf> if Ok, «E»<cr><lf> if error,
«W»<cr><lf> if coherency error
«O»<cr><lf>, «W»<cr><lf> if coherency error
«O»<cr><lf>, «W»<cr><lf> if coherency error
«O»<cr><lf>
Response Syntax to Next Line
CONNECTING...
CM
E -> This command is not validated (register no unloc-
ked)
O
O
S202=1
O
O
Page
72
of 100

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Arf8230caArf8230ga

Table des Matières