Transmitting A Daily Frame; Leaks Detection - ADEUNIS sigfox Pulse 868 Guide Utilisateur

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

sigfox Pulse - Guide utilisateur / User guide version V2.0.0
Register
Value encoding
S320
Hexadecimal
FR
S332
Decimal
S333
Decimal
S334
Decimal
EN
S335
Decimal

2.2.5 Transmitting a Daily Frame

The product transmits every 24 hours a daily frame (0x30) according to the following diagram:
The transmission period of the daily frame is fixed (24 hours) and not configurable.

2.2.6 Leaks detection

The product allows leak detection on each count input as shown in the following diagram:
The flow rate corresponds to the number of pulses of the flow calculation period divided by the same period. It is expressed in pulses / hour.
Value
Result
0x39
Channel A :
Channel B :
2
Scan period for A-channel tamper input is 2x10s = 20s
3
Tamper detection threshold for A-channel = 3 (positive scans of
B-channel tamper before triggering the tamper alarm)
2
Scan period for B-channel tamper input is 2x10s = 20s
3
Tamper detection threshold for B-channel = 3 (positive scans of
B-channel tamper before triggering the tamper alarm)
Product in standby
Period of
No
24h reached
?
Yes
Send frame 0x30
Initialization of min
and max flow rates
Initialization of alarm
states
Activated
Meter other than gas
Tamper input activated
Activated
Gas meter
Tamper input disabled
Page