1.4. Using the product with default settings

1.4.1 Daily frame

This frame (0x30) is transmitted 24 hours after the startup of the application or after the transmission of the previous Daily frame.
0
1
Code
Status
0x30
Cf Status
0x30
0xA3
Its size is of 11 bytes.
Description of the frame:
Byte 2 : Alarms state (bit to 1 if the alarm is activated else 0) :
Bit 0 – Exceeding flow on channel A
Bit 1 – Exceeding flow on channel B
Bit 2 – Tamper detected on channel A
Bit 3 – Tamper detected on channel B
Bit 4 – Leak detected on channel A
Bit 5 – Leak detected on channel B
Bit 6/7 – Reserved
Bytes 3 to 4 : maximum measured flow on channel A within the last 24 hours.
Bytes 5 to 6 : maximum measured flow on channel B within the last 24 hours.
Bytes 7 to 8 : minimum measured flow on channel A within the last 24 hours.
Bytes 9 to 10 : minimum measured flow on channel B within the last 24 hours.
In the example in grey this gives:
Byte 2 : Alarms = 0x19 so as (00011001) binary which gives:
Bit 0 = 1 – Exceeding flow on channel A
Bit 1 = 0 – No exceeding flow on channel B
Bit 2 = 0 – No tamper detected on channel A
Bit 3 = 1 – Tamper detected on channel B
Bit 4 = 1 – Leak detected on channel A
Bit 5 = 0 – No leak detected on channel B
Bit 6/7 – Reserved
Bytes 3 à 4 : maximum measured flow on channel A within the last 24 hours.= 0x310A so 12,554 pulses per hour.
Bytes 5 to 6 : maximum measured flow on channel B within the last 24 hours.= 0x12C4 so 4,804 pulses per hour..
Bytes 7 to 8 : minimum measured flow on channel A within the last 24 hours.= 0x0010 so 16 pulses per hour..
Bytes 9 to 10 : minimum measured flow on channel B within the last 24 hours. = 0x0000 so 0 pulse per hour..
As a reminder, the alarms are automatically deactivated after the daily frame is sent.