5.4. Closing the casing

Once previous stages have been carried out, you can close the casing of the sigfox Pulse
Procedure:
1.
Make sure that the seal is properly positioned on the base
2.
Clip the electronic board onto the casing's base. Make sure that the fastening clip is properly locked into the board's fitting.
3.
Insert the upper part of the casing. Inside this part there are guide rails for the board. Make sure that the board is properly positioned
FR
within these guides.
4.
Once the board is in position, lower the upper cover and lock it onto the casing's base. Strong pressure will enable both parts to be
clipped together and will enable protection level IP67 to be ensured.
5.
Finish the assembly by locking the packing gland's nut in position
1
EN
3/4
Locking clips for the
upper casing

5.5. Starting up the product using a magnet

Once the product has been configured and its
assembly has been finalised, the product is ready
to be started up.
The start-up is carried out using a magnet which
you place on the upper part of the product (cf.
the diagram below). The magnet must be held in
position for at least 6 seconds so as to confirm the
start-up of the product. When the magnet is well
detected, the green LED lights up for 1 second.
Once the sigfox Pulse unit validates its start-up, it
immediately transmits status frames followed by a
data frame (according the defined periodicity).
.
Seal
Fastening clip
Packing gland nut
2
Fitting
5
Position of the magnet for
starting up the product