3.3. AT commands

A command starts with 2 ASCII characters: "AT", followed by one or more characters and data (see the list below
for the syntax of AT commands available on the modem).
Each command must finish with a "CR" or "CR" "LF" – both are acceptable.
(CR indicates: Carriage Return, LF indicates: Line Feed)
Once the command has been received, the modem will feedback:
<cr><lf> "Data" for ATS type playback control <n> ?, AT/S or AT/V
FR
"O" <cr><lf>, for any other command when this has been accepted.
"E" <cr><lf>, if it refuses the command due to a syntax error, unknown command, unknown range, invalid para-
meter, etc.
"CM" <cr><lf>, if it accepts the input in command mode
Table of AT commands:
EN
Command
+++
ATPIN <PIN>
AT/V
AT/N
ATS<n>?
AT/S
ATS<n>=<m>
AT&W
ATO
ATT63 PROVIDER
Example of a set of commands and corresponding responses that can be seen on the terminal:
Syntax
of the order
+++
ATS202=1
ATT63 PROVIDER
ATS202=1
ATS202?
AT&W
ATO
Interpreting the previous example: the user wanted to modify the number of repetition after having made an
unauthorised command (answer E), and the ranges were unblocked in order to modify the range. The range S202
was verified and the parameters were saved before exiting. When exiting command mode, the device will start a
new cycle of emission.
Description
Input request in command mode
Gives access to AT commands if register S304 is
different of 0
Feeds back the version of the APPLICATIF and
RTU software
Feeds back the type of network
Feeds back the content of the n range
Edits the content of all of the user ranges in the
form of a list.
Transfers the m value to the n range
Saves the current configuration to non-volatile
memory.
Exit command mode
Unblock the operating range
Description
Input request in command mode
Changing the number of repetitions
Unblock the operating range
Changing the number of repetitions
Feeds back the value of the S202 range
Memory request for the state range
Output request in command mode
Reply example
CONNECTING... <cr><lf>
CM<cr><lf>
APP_8230EAA_PRG1706_V01.02.02:RTU_
RTU_WMBUS_868_PRG_1601_V00.00.03
Ou selon la version du réseau
APP_8181AAA_PRG1701_
V01.00.02:RTU_8120AAB_PRG_1701_
V01.00.01
"LoRa" ou "SIGFOX" or « WMBUS »
S<n>=<y><cr><lf> with <y> as the
register content
/
«O»<cr><lf> if Ok, «E»<cr><lf> if error,
«W»<cr><lf> if coherency error
«O»<cr><lf>, «W»<cr><lf> if coherency
error
«O»<cr><lf>, «W»<cr><lf> if coherency
error
«O»<cr><lf>
Response Syntax to Next Line
CONNECTING...
CM
E -> This command is not validated (register
no unlocked)
O
O
S202=1
O
O
Page