sigfox RC1 PULSE IP68 - Guide utilisateur / User guide version V4.0.0
Example :
Register
Value encoding
S320
Hexadecimal
FR
S322
Hexadecimal
S325
Decimal
EN
S328
Decimal
S329
Decimal
S330
Decimal
S331
Decimal
In this example, all the periods during which the flow rate on the channel A is less than 10 pulses / hour are considered as periods of zero flow.
If the total daily number of zero flow periods is less than 3 then it is considered that there is a leak on the channel A.
2.3. Operation of the LEDs
Mode
Product in Park mode
Magnet detection process (1 to 6 seconds)
Product start (after detection of the magnet) OFF
Switching to the Command mode
Product faulty (return to factory)
Value
Result
0x39
Channel A :
•
Activated
•
Meter other than gas
•
Tamper input activated
Channel B :
•
Activated
•
Gas meter
•
Tamper input disabled
0x57
Anti-bounce :
•
Channel A = 500ms
•
Channel B = 100ms
60
Flow calculation period (channels A and B) = 60min
10
Leak threshold (channel A) = 10 pulses par hour
0
Leak threshold (channel B) = 0 pulse par hour
3
Daily periods number under the leak threshold (channel A) = 3
5
Daily periods number under the leak threshold (channel B) = 5
LED red state
OFF
OFF
Continuously lit
Fixed ON
LED green state
OFF
ON from detection of the magnet up to a
maximum of 1 second
Rapid flashing 6 cycles, 100 ms ON / 100
ms OFF
Continuously lit
Page
48