2.1.8 Product output control(s)

The product allows configuring all or part of the digital outputs in order to control them from the network by a downlink frame as shown in the
following diagram:
Product in standby
Event or period
reached ?
Yes
Send frame 0xXX
Frame reception 0x60
ou 0x61
Update states of digital
input configured at the
output

2.2. Operation of the LEDs

Mode
Product in Park mode
Magnet detection process (1 to 6 seconds)
Starting the product (after detection of the
magnet)
Switching to command mode
Low battery power level
Defective product (factory return)
Detection of the magnet in operating mode
The parameters associated with this operating mode are:
• The configurations of the different digital inputs/outputs (registers 380 and 382)
The complete list of registers may be found in section 3.4.
Example :
No
Register Value coding
S380
Hexadecimal
S382
Hexadecimal
In this example, I/O 2 is configured as an output with a default state of 1.
Red LED State
Off
Off
Off
Fixed on
Flashing (0.5 s ON every 60s)
Fixed on
Off
Value
Result value
0x73
Configuration of the Digital Input/Output 1:
• Periodic mode
• Counting of high and low fronts
• 1 second guard period
0x05
Configuration of the Digital Input/Output 2:
• Output (default state= 1/CLOSE)
• No on-call period
Green LED State
Off
ON as soon as the magnet is detected for
up to 1 second
Fast flashing 6 cycles 100 ms ON/ 100 ms
OFF
Fixed on
-
-
Flashing 50ms ON / 50ms OFF as soon as
the magnet is detected for up to 3 seconds