1.4. Technical Specifications

1.4.1 General characteristics

Parameters
Supply voltage
Power supply
Operating temperature
Dimensions
Case
Sigfox Zone
Max transmit power

1.4.2 Autonomy

Use Case
Number of shipments per day: 144 frames (72 for the Delta P and 72 for the 0-10V
range)
DELTA P sampling period: 1 minute
Input sampling period 0-10 V: 1 minute
Number of Channel1 events: 86400 (theoretical max at 1 event per second)
Number of Channel2 events: 86400 (theoretical max at 1 event per second)
Number of shipments per day: 12 frames
DELTA P sampling period: 20 minutes
Input sampling period 0-10 V: 30 minutes
Number of Channel1 events: 0 (Channel disabled)
Number of Channel2 events: 0 (Channel disabled)
Number of shipments per day: 2 frames
DELTA P sampling period: 10 minutes
Input sampling period 0-10 V: 0 (0-10V range disabled)
Number of Channel1 events: 0 (Channel disabled)
Number of Channel2 events: 0 (Channel disabled)
Number of shipments per day: 24 frames
DELTA P sampling period: 10 minutes
Input sampling period 0-10 V: 0 (0-10V range disabled)
Number of Channel1 events: 0 (Channel disabled)
Number of Channel2 events: 0 (Channel disabled)
Number of shipments per day: 48 periodic frames and 30 alarms
DELTA P sampling period: 10 minutes
Input sampling period 0-10 V: 10 minutes
Number of Channel1 events: 10
Number of Channel2 events: 20
The above values are estimates made under certain operating and environmental conditions (25°C and 1 year of storage). They do not represent
any guarantee made by adeunis.
Value
Nominal 3.6V
Removable LiSOCl2 FANSO (battery-pack ER18505H+W36+51021)
-20°C / +70°C
200 x 63.5 x 34 mm
IP68
RC1
14 dBm
Autonomy (years)
< 1.0
4.1
9.8
2.4
1.3
EN
Page
37
of 50