3.1 Alternative facilities
3.1.1 Exterior fittings
Exterior fittings according to DIN 18273 with valid proof of conformity may be
used.
3.1.2 Special keeps / electrical door opener
Alternatively to the standard keeps the lock, except of panicLock
T-AP 179 AV3 OR, may also be furnished with special keeps and electrical ope-
rating current door openers of the type series:
GEZE (formerly IST):
effeff / ASSA ABLOY:
dormakaba Deutschland (DORMA): Fire 447 and Smoke 117
be equipped.
When using electric release effeff / ASSA ABLOY 19, 116, 118, 119, 611 and IST A
7000 each classification scheme at the 4th position (proof of suitability for fire
barriers) = unsuitable enter a 0 zero.
Example:
Door openers with a day release function, with the exception of T-AP179 AV3 OR
FF, are only permitted if they are not used in fire and smoke protection doors.
For the lock T-AP179 AV3 OR, the daytime latch T-Tagesfalle TAFA can be used
for day release function (not for use in fire and smoke protection doors).
Door openers with a day release function and / or quiescent current version to
EN 1125 are not allowed.
Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen
T +49  369  3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes