2.1 panicLock AP4 for single sash and double sash doors
The mechanical anti-panic locking systems in variation panicLock AP4 (accor-
2
ding to DIN EN 179 and DIN EN 1125), each with
• Change-over function B (divided follower)
• Transit function D (divided follower)
• Switching function E (continuous follower),
fulfil all requirements for a quick opening function from the inside, yet still pro-
vide protection from the outside thanks to the sturdy hooks. Suitable for single
sash doors and / or double-sash doors made from aluminium, wood and PVC-U.
Easy installation of the double sash solution by leaving out stud rods or self-
triggering, flush shoot bolt.
Winkhaus panicLock AP4 requires a profile cylinder, usually with a cam position
± 30°, with a smooth-running free to turn function or rigid cam position.
2.2 panicLock blueMotion, fully motorised multi-point
locking system with switching function E
The fully motorised blueMotion anti-panic locking system in the version as pa-
nicLock BM EN179 (according to DIN EN 179) and as panicLock BM EN1125 (ac-
cording to DIN EN 1125) ensures safe motorized locking and unlocking of escape
doors - in addition to the usual mechanical escape door - unlocking from the in-
side. Suitable for single sash doors and / or double-sash doors with a fixed sash,
made of aluminum, wood and PVC-U.
Only use panic profil-cylinders with free moving cam with anti-blockade func-
tion and cam position max. ± 30°!
With panicLock BM, the approved battery pack T-HT AKKU MIT LADESCHAL-
TUNG 24 V DC must always be used.