Fasten the locking
cylinder with the
cylinder fixing screw
Check for complete
functionality
Fig. 6 :
No transverse shear
stress on the bolt after
installation
EN
48

Installing fittings and locking cylinders

1
Install the fittings.
2
Insert the locking cylinder and ensure that the locking cylinder nose is in the centre position (Fig. 16).
3
Fix the locking cylinder into place with the fixing screw.
 The multi-point lock 319N is completely installed.

Testing the multi-point lock 319N

1
Test all functions of the multi-point lock 319N.
2
Check whether the latch and control latch of the lock are pushed back by the same impact edge.
3
Check whether all bolts can freely extend and retract without transverse shear stress after installation
(Fig. 6).
 The multi-point lock 319N is completely installed and has been tested for functionality.