1. Oven(s) are uncrated and put in place.
2. The owner/operator must have the following
plumbing and electrical requirements met and
installed.
NOTE: Refer to the Utility Connection infor-
mation provided.
Water
Water Pressure (min/max)
Cold Water Connection
Hot Water Connection*
Pressure Regulator Setting
Drainage
Drain Connection
Avg Water Drain Temp.
Electrical
By Mode
y
Blower Motor
* Not applicable with COS-20EDS, BCS-20DS and CNV-20E.
PLUMBING
40 PSI min/50 PSI max
3/4" Hose Fitting, 3/8" ID hose minimum
3/4" Hose Fitting*, 3/8" ID hose minimum
35 PSI Preset
Atmospheric Vented Drain
2" NPT
122_F (50_C)
ELECTRICAL
61kw
Steam
45kw
Hot Air
60kw
Combi
60kw
1 hp / 1 kw
Installation
Owner's Responsibilities
WARNING!!
Improper installation, adjustment, alter-
ation service or maintenance can cause
property damage, injury or death. Read
the installation, operation and mainte-
nance instruction thoroughly before in-
stalling or servicing this equipment.
Amp/Line (max)
Volt
3 Phase
208
170
240
147
480
74
5
1 Phase
N/A
N/A
N/A