7��
Replace plug in drain valve��
8��
Refill the machine following the "top up coolant"
procedure above�� After initial fill, to purge any
airlocks, the machine should be run for a few
minutes cycling between load and no load, before
checking that the level is correct��
9��
Replace and tighten coolant fill cap��
COOLANT FILTER CHANGE PROCEDURE
1��
Stop the machine, electrically isolate and vent all
trapped pressure��
2��
Loosen filter with the correct tool��
3��
Remove the filter from the housing��
4��
Place the old filter in a sealed bag and dispose of in a
safe way��
5��
Clean the mating face of the housing taking care to
avoid any particles entering the machine��
Remove the new Ingersoll Rand replacement filter
6��
from its protective package��
7��
Apply a small amount of lubricant to the filter seal��
8��
Screw the new filter down until the seal makes
contact with the housing, then hand tighten a
further half turn��
9��
Start the compressor and check for leaks��
AIR FILTER ELEMENT CHANGE PROCEDURE
1��
Stop the machine, electrically isolate and vent all
trapped pressure��
2��
Unscrew the retaining cap and withdraw the old
element��
3��
Fit the new element��
4��
Replace the retaining cap��

RELEASED 20/Jul/2016 17:56:55 GMT
All manuals and user guides at all-guides.com
MAINTENANCE
SEPARATOR CARTRIDGE CHANGE PROCEDURE
1��
Stop the machine, electrically isolate and vent all
trapped pressure��
2��
Loosen separator cartridge with the correct tool��
3��
Remove the cartridge from the housing; place it in a
sealed bag and dispose of it safely��
4��
Clean the mating face of the housing��
Remove the new Ingersoll Rand replacement
5��
cartridge from its protective package��
6��
Apply a small amount of lubricant to the cartridge
seal��
7��
Screw the new cartridge down until the seal makes
contact with the housing, then hand tighten a
further 1/4 turn��
8��
Start the compressor and check for leaks��
This unit is not designed or intended to operate
when contaminated with silicone�� Lubricants,
greases or other items containing silicone should
not be used on this unit��
COOLER CLEANING PROCEDURE
1��
Stop the machine, electrically isolate and vent all
trapped pressure��
2��
Remove the top cover to obtain access to the cooler��
3��
Clean the cooler��
4��
Rebuild in reverse order��