OPERATING INSTRUCTIONS (XE-70M CONTROLLER)
Table 6 : Dashboard Icons
Name
Icon
Description
Remote
Remote control is enabled�� This
Control
can be Remote Start/Stop, COM
Control, Integral Sequencing or
Web Control��
Service
A service reminder is nearing or
Required
has expired
(i��e��: an air or oil filter needs to be
changed)��
Unloaded
Compressor is in the unloaded
state��
or
Loaded
Compressor is in the loaded state��
DASHBOARD STATUS MESSAGES
The dashboard also displays the current operating
state of the compressor�� The following states can be
encountered during machine operation:
Ready to Start – The compressor currently has no trip
or start inhibit conditions present�� The machine can be
started by pressing the start button at any time��
Starting – A start command has been given to
the compressor and the start sequence is being
performed�� The time period for this state can vary
depending on the starter type of the machine��
Load Delay – The compressor is waiting for a small
period of time after starting before allowing the
machine to load�� This ensures the machine is at
operating conditions before loading��
Running Loaded – The compressor is operating and
producing air�� The inlet valve is open and the blow-off
valve is closed��
Running Unloaded – The compressor is operating,
but not producing air�� The inlet valve is closed and the
blow-off valve is open��
Reload Delay – This is a brief period of time after the
compressor has unloaded before it is allowed to load
again�� This gives the inlet and bypass valves time to
reach their proper positions��
Auto-Restart – The compressor has stopped due to
pressure rising above the offline or auto-stop setpoints
and auto-restart being enabled�� The compressor will
automatically restart when pressure falls to the online
or target pressure setpoint��
Stopping – The compressor has received a stop
command and the stop sequence is being performed��
Blowdown – The compressor must wait for a brief
period of time after stopping its motor before it is
allowed to start again�� The compressor will restart at
the end of the blowdown period if a start command is
recieved during blowdown��
Not Ready – The compressor has detected a condition
that will not allow the compressor to start�� The
condition must be cleared before a start is allowed, but
does not need to be acknowledged��
Tripped – The compressor has detected an abnormal
operational condition that has stopped the machine�� A
trip must be acknowledged by hitting the reset button
before the compressor can start��
Processor Init – The controller is being initialized��
10
RELEASED 20/Jul/2016 17:56:55 GMT
All manuals and user guides at all-guides.com
FIXED SPEED COMPRESSOR
Page 1: System Overview
This is the factory default display after powering up the
system��
Online Pressure Setpoint - indicated in the black box
and arrow, which is always left of center on the gauge��
The compressor will load when package discharge
pressure falls below this value��
Offline Pressure Setpoint - indicated in the black
box and arrow, which is always right of center on the
gauge�� The compressor will unload when package
discharge pressure rises above this value��
Package Discharge Pressure - indicated by the large
numbers centered below the gauge and by the black
arrow below the gauge�� This is the air pressure that the
compressor is supplying to the plant��
Pressure Unit of Measure - indicated below the
Package Discharge Pressure�� This is selectable from the
GENERAL SETTINGS folder��
Airend Discharge Temperature - indicated by the
numbers in the lower right of the display�� This is the
temperature of the air/oil mixture at the discharge of
the compression module��
Temperature Unit of Measure - indicated to the right
of the Airend Discharge Temperature�� This is selectable
from the GENERAL SETTINGS folder��
Run Hours – indicated by the numbers in the
lower left of the display�� The number of hours the
compressor motor has been running��
The online and offline set points can be selected and
modified on this page�� All other information on this
page is read only��
HOME FOLDER
Figure 5 : Home Folder
NOTICE
80448418 Rev.C