The "Electrical supply plate" module (5) interrupts the incoming supply volt-
age UA. The supply voltage of this module is used for all valves located to the
right of the electrical supply plate. The "Electrical supply plate" module can be
used several times in the valve area.
The voltage UL is galvanically isolated from the voltage UA in the valve system.
2
7
6
8DO8M8
8DI8M8
8DI8M8 AES-D-BC-...
FB
Fig. 14: Assignment of the supply voltages UL and UA
1 Bus coupler
3 Valve Zone
5 electrical supply plate
7 Input module
9 Valve driver board, 4x
11 Valve
UL 24 V supply voltage for the electron-
ics and logic
FB Fieldbus

3.9 Wiring concepts of the valve system

The 3 figures below show the various wiring concepts of the valve system.
The following applies to all 3 representations:
• The power supply at the bus coupler (K1) for UL and UA is provided via plug
X1S1.
• The supply of the safe supply voltage for the valves is always made via the
connection of the additional electrical supply plate (X1S2) of the valves.
For the following wiring concepts, the equipment with the reference
designations based on EN 81346 is used. The examples only show the
relevant section of the power supply and are not complete. For the ap-
plication within a machine, additional equipment is necessary.
See g Fig. 14. In the wiring diagram, a common power pack (L01) is used for
both voltages UL and UA. The voltage for the valves at connection X1S2 is
switched off in 2 poles (i.e. UA+ and UA-) via the safety module.
AVENTICS™ AV | R412018148-BAL-001-AB | English
3
8 9
5
1
P
UA
UL UA
2 I/O modules
4 Part of the safety-related control
chain
6 Output module
8 pneumatic supply plate
10 Supply board
12 Safety module
UA 24 V supply voltage for the actuators
L01_24V
L01_0V
4
11
10
Fig. 15: Wiring concept 1
12
-K1
Valve system with 2 plugs for
power supply
-X1S1
Connection for the power supply of
the bus coupler
-F1
Fuse for voltage UL
-X2
Terminal strip
In the following example, 2 separate power packs are used for both voltages UL
(L01) and UA (L02). The voltage for the valves at connection X1S2 is switched off
in 2 poles (i.e. UA+ and UA-) via the safety module.
L01_24V
L01_0V
L02_24V
L02_0V
Fig. 16: Wiring concept 2
-K1
Valve system with 2 plugs for
power supply
-X1S1
Connection for the power supply of
the bus coupler
-F1
Fuse for voltage UL
-X2
Terminal strip
In the following example, a shared power pack (L01) is used for both voltages UL
and UA. The voltage for the valves at connection X1S2 is switched off single-pole
UA+ via the safety module.
-F2
-F1
-K2
-X2
31 32 33 34
PE
-X1S1
-X1S2
2
4
1
3
1
K1
UA+
UA-
UL+
UL-
nc
-K2
Safety module
-X1S2
Connection for the power supply
of the electrical supply plate
-F2
Fuse for voltage UA
L0x
Power supply
-F1
-F2
-K2
-X2
31 32 33 34
PE
41 42 43 44
-X1S1
-X1S2
2
4
1
3
1
-K1
UA+
UA-
UA+
UL+
UL-
nc
-K2
Safety module
-X1S2
Connection for the power supply
of the electrical supply plate
-F2
Fuse for voltage UA
L0x
Power supply
13
23
14
24
41 42 43 44
PE
2
4
3
UA+
UA-
nc
13
23
-K2
14
24
PE
PE
2
4
3
UA-
nc
21