Eclipse 5
Guidance and Manufacturer's Declaration—Electromagnetic Immunity
The Eclipse 5 is intended for use in the electromagnetic environment specified below. The customer or the user
of the Eclipse 5 should assure that it is used in such an environment.
Immunity test
Electrostatic discharge
(ESD) IED 61000-4-2
Electrical fast transient/
burst
IEC 61000-4-4
Surge
IEC 61000-4-5
Voltage dips, short in-
terruptions and voltage
variations on power
supply input lines IEC
61000-4-11
Power frequency magnet-
ic field IEC 61000-4-8
Conducted RF
IEC 61000-4-6
Radiated RF
IEC 61000-4-3
26 - ENG
PN 21182453-C4 F | User Manual
Compliance level
±8 kV contact
±15 kV air
±2 kV
±1 kV
±2 kV
100V-240V
30A/m
10 Vrms
150 kHz to 80 MHz
9 V/m to 85 V/m
At frequencies, up to
5.785GHz
Electromagnetic environment – guidance
Floors should be wood, concrete or ceramic tile.
If floors are covered with synthetic material, the
relative humidity should be at least 30 %.
Mains power quality should be that of a typical
commercial or hospital
environment.
Mains power quality should be that of a typical
commercial or hospital
environment.
Mains power quality should be that of a typical
commercial or hospital environment. If the user of
the Eclipse 5 requires continued operation during
power mains interruptions, it is recommended that
the Eclipse 5 is powered from an uninterruptible
power supply (UPS).
Power frequency magnetic fields should be at levels
characteristic of a typical location in a typical com-
mercial or hospital environment.
The Eclipse 5 complies with all applicable electro-
magnetic compatibility requirements (EMC) accord-
ing to IEC 60601-1-2:2014, for residential, commer-
cial and light industry environments. Portable and
mobile RF communications equipment should be
used no closer to any part of the machine, including
cables, than the recommended 10cm separation
distance. The Eclipse 5 has been designed to meet
EMC standards. However, should you suspect that
the machine performance (e.g. pressure or flow)
is affected by other equipment, move the machine
away from the possible cause of the interference.
The Eclipse 5 complies with Part 15 of the FCC rules
and industry Canada license-exempt RSS standards.
Operation is subject to the following two conditions:
this machine may not cause harmful interference,
and this machine must accept any interference
revived, including interference that may cause
undesired operation.
FCC ID: WAP2001