Menu
Undermenu
Selection
AMP.N
AMP.R
On / oFF
A.PR1
0 - 100%
AMP.S
A.PR2
0 - 100%
VAL.A
ESC
DEF1
not / YES
L.DeF
DEF2
not / YES
ESC
Sho.C
Cont
dEL.C
ESC
inFo
On
It enables / disables the motors' current reading necessary to detect the obstacles. Disabling this
oFF
function, all other following undermenu of the AMP.S menu have no effect.
It enables / disables the motors' current reading during the slow-down phase.
Setting of the M1 motor's current limit to pass for detecting the obstacle
Setting of the M2 motor's current limit to pass for detecting the obstacle
It shows in sequence the current values, detected by the device, in the following order:

Maximum current at M1 motor's normal speed

Minimum current at M1 motor's normal speed

Maximum current at M1 motor's slow-down speed

Minimum current at M1 motor's slow-down speed

Maximum current at M2 motor's normal speed

Minimum current at M2 motor's normal speed

Maximum current at M2 motor's slow-down speed

Minimum current at M2 motor's slow-down speed
Return to AMP.S menu
It predisposes the card for the operation with a single wing gate and the Default values
It predisposes the card for the operation with a 2-wings gate and the Default values
Return to L.DeF menu
It shows the number of cycles carried out by the automation (cycles counter)
It erases the cycles counter
Return to Cont menu
It shows the software version of the electronic card
Description
42
ENGLISH
Default
on
oFF
30%
30%

Publicité

Table des Matières
loading

Table des Matières