In any operation mode, the safety devices causes the following effects :
Stop : If the stop command is enabled no cycles can start and the start command will have no effect. If a stop command is supplied during motion,
the gate will immediately stop e interrupt its operating cycle. This condition will continue until the stop command is on. A start command
following a stop command always determines an opening cycle. A stop command supplied during the pause period interrupts the operating
cycle. A start command subsequently supplied will start a closure cycle.
Photo-cell : This device has effect only during the closure phase or in the pause period. If an obstacle covers the photo-cell during the closure phase ,
the gate stops and reverses its motion after approx. 2 sec. If an obstacle covers the photo-cell during the pause period this last one is
reset and the automatic closure is therefore delayed. .
Photostop : If an obstacle covers the photo-cell during the gate's motion (opening or closure), or during the period preceding the operating cycle's
start, then the gate is temporarily stopped, until the obstacle is not removed. The blinker will light with a fixed light to signal the irregular
condition. When the obstacle is removed and the photocell is freed, an opening cycle will start. This does not apply when a start
command determines the closing phase in step-by-step mode at the end of an opening cycle. If an obstacle covers the photostop during
the pause period this last one is reset and the automatic closure is therefore delayed.
Pedestrian start: The pedestrian start command operates in the same way as the other start command, but in this case only the wing fitted with the
electric lock (M2) will be opened or closed. The pedestrian start command has no effect during a start cycle and up to the end of
the closing phase (closed gate). During a pedestrian start cycle the start command is always active and causes the start of an
opening cycle for both wings. The pedestrian start command determines the complete opening of the shutter M2 in case of a
2-wings gate. It determines the partial opening of the shutter M2 in case of a single-wing gate (Pedestrian Time).

13) Electrical and mechanical specifications

Dimensions and weight (with box) : 186 x 283 x 112 mm - 2,3 Kg
Mains power supply : 230Vac +/- 10%
Stand-by power consumption : approx. 1W
Operating temperature range : 0 to + 60°C
Single-phase motors power supply : 230Vac 1HP max
Blinker power supply : 230Vac 40W max
Courtesy light power supply : 230Vac 150W max
Open gate lamp power supply : 12Vac (JP1 1-2) or 24Vac (JP1 2-3) - 4W max
Electric lock power supply : 12Vac 15W max
Accessories power supply : 24Vac 0.5A max
Motors' work time : programmable, 0 to 120 sec.
Pause time : programmable, 0 to 120 sec.
nd
2
wing closing delay : programmable, 0 to 30 sec.
Storable remote controls : 50 max.