Terminal board J1
Terminal 1 – Electric lock 12Vac power supply (common)
Terminal 2 – Electric lock 12Vac power supply
Terminal 3 – 24Vac power supply for photocells or other devices (common)
Terminal 4 – 24Vac power supply for photocells or other devices
Terminal 5 – Common Terminal for all electric contacts of commands or security devices
Terminal 6 – Photoelectric cell's normally closed electric contact (photostop)
Terminal 7 – Photocell's normally closed electric contact
Terminal 8 – Emergency push-button's normally closed electric contact (stop)
Terminal 9 – Pedestrian start push-button's normally open electric contact
Terminal 10 – Start push-button's normally open electric contact
Important: The normally closed inputs not in use must be fitted with jumpers (shunt)
Terminal board J8
Terminal 1 – Courtesy light's 230Vac power supply phase
Terminal 2 – Courtesy light's 230Vac power supply neutral
Terminal board J9
Terminal 1 - Power supply of Open-gate lamp or photocells Test
Terminal 2 - Power supply of Open-gate lamp or photocells Test
Terminal board J5
Terminal 1 – Aerial cable connection (shield) for radio receiver
Terminal 2 – Aerial cable connection (signal) for radio receiver
Connector J6
Terminal 1 – Normally open electric contact connected to the start
Terminal 2 – Common of the normally open electric contact connected to the start
Terminal 3 – Normally open electric contact connected to the pedestrian start
Terminal 4 – Common of the normally open electric contact connected to the pedestrian start
Terminal 5 - 12Vdc power supply negative (common)
Terminal 6 - 12Vdc power supply positive
Terminal 7 - 12Vdc power supply positive
Terminal 8 - 12Vdc power supply negative (common)
Terminal 9 – Aerial input (shield)
Terminal 10 – Aerial input (signal)