Connection of the devices
230 Vac mains power supply cable – Terminals 1,2 and 3 on J7
Warning: The cable's ground pole must be connected to a good ground reference in the gate's nearby area.
Motor 1 – Terminals 1, 2 and 3 on J2
Motor 2 – Terminals 4, 5 and 6 on J2
Blinker – Terminals 7 and 8 on J2
Electric lock – Terminals 1 and 2 on J1
Photocells power supply – Terminals 3 and 4 on J1
NC photocell contact – Terminals 5 and 7 on J1
NC stop push-button – Terminals 5 and 8 on J1
NC photostop contact – Terminals 5 and 6 on J1
NO pedestrian start push-button – Terminals 5 and 9 on J1
NO start push-button – Terminals 5 and 10 on J1
Aerial – Terminals 1 and 2 on J5
Courtesy light– Terminals 1 and 2 on J8
Open gate lamp – Terminals 1 and 2 on J9
Photocell Test power supply - Terminals 1 and 2 on J9
NC Motor 1 opening limit switch contact – Terminals 1 and 4 on J3
NC Motor 1 closing limit switch contact – Terminals 2 and 4 on J3
NC Motor 2 opening limit switch contact – Terminals 5 and 8 on J3
NC Motor 2 closing limit switch contact – Terminals 6 and 8 on J3
Motor 1 Encoder connection - Terminals 3 and 4 on J3
Motor 2 Encoder connection - Terminals 7 and 8 on J3
IMPORTANT :

If at Start-up the contacts FC1A and FC1C are both opened, the control of Motor 1 limit switches will be automatically disabled.

If at Start-up the contacts FC2A and FC2C are both opened, the control of Motor 2 limit switches will be automatically disabled.
Important : Before starting the gate check the following conditions :
a) connections to the electronic card
b) electric contacts' switching
c) state of the protection fuses