M1 delay at opening
The unit is pre-programmed with a fixed delay of approx. 2 seconds between the first wing's (M2) and the second wing's (M1) start during the gate's
opening phase. This delay is imposed irrespective of the position from which the gate starts to open. This delay may be changed by programs menu.

12) Operation modes

Introduction
The electronic unit contains a microprocessor to control the gate's operation modes. These are four main operation phases :
Phase preceding the gate's motion
Gate's fast motion phase
Gate's slow motion phase
Gate's pause phase (open gate)
The unit can function in three modes : Step by step , Automatic and Condominium.
The start of working cycle is always enabled by a Start or Pedestrian start control.
Important : Whatever logic has been selected, the first Start command after the power is supplied to the electronic card will always cause the start of
an opening cycle.
"Step-by-step" mode
After the power is supplied to the electronic card the first start command determines an opening cycle. At the end of the two work times the gate stops.
The operating cycle is completed (blinker off) and the system waits for a new start command to determine the closing cycle. If a start command is
supplied when the end of travel has not been reached yet the gate stops. A new start command will cause the reversal of the motion.
"Automatic" mode
After the power is supplied to the electronic card the first start command determines an opening cycle. At the end of the two work times the gate stops.
The pause period starts. At the end of the pause period the gate closes automatically. The operating cycle is complete only when the closing motion
has ended (blinker off). If a start command is supplied before the end of travel is reached the gate stops. A new start command will cause the gate to
reverse its motion. If a start command is supplied during the pause period the operating cycle is interrupted and the gate does not close automatically.
A further start command will determine a closing cycle.
"Condominium" mode
After the power is supplied to the electronic card the first start command determines an opening cycle. At the end of the two work times the gate stops.
The pause period starts. At the end of the pause period the gate closes automatically. The operating cycle is complete only when the closing motion
has ended. If a start command is supplied while the gate opens, the command will have no effect. If a start command is supplied while the gate closes,
the gate will stop and reverse its motion after approx. 2 sec. If a start command is supplied during the pause period, the period will be reset and the
automatic closure will start later.
Important : If the gate opening is controlled by a clock the "condominium" mode must be enabled.
"Single wing" mode
This mode is employed with single-wing gates. When enabled, it drives the motor M2 only. The operating modes described above remain unchanged.