C) – Installation
1)
Remove the cover and check that the electronic unit is in good order. In case of doubt do not install the unit and ask for the intervention of
qualified personnel. The container's accessories (screws, round seal, cable glands) must not be left within the reach of children since they are
a potential danger.
2)
Check that the electronic unit and the accessories are properly fixed to the box. If not, tighten all screws or provide the missing screws.
3)
Place the unit near the gate so that the system connection wires' length is reduced to the minimum.
Caution: For the unit's correct operation the wires connected to it must not be longer than 10 metres.
4)
For increased weather protection we recommend to place the unit under a roof or, even better, in an enclosure having two side walls.
Moreover it is necessary to install the unit at a minimum 1,5 mt level above the ground to keep it out of the reach of children.
5)
Before proceeding to assembly place the container so that the side fitted with the cable glands is directed towards the ground.
Caution: Do not assemble the container on wood surfaces.
6)
Insert the supplied round seal in its seat. Make sure the two ends meet at the centre of the side to which the cable glands are fitted.
7)
Lift the mobile portion of the connector and proceed to connect the unit wires as described in the following chapters.
D) - Operation
1) Definitions of Controls
Start
Input connected to a push-button placed outside the unit. It is employed to request the gate's opening or closure (for both wings). This input is usually
connected to a key push-button.
Pedestrian Start
Input connected to a push-button placed outside the unit. It is employed to request the opening or closure of one wing only (pedestrian wing) to allow
the passage of persons or animals.
2) Definitions of Safety devices
Stop
Input connected to a push-button or switch placed outside the unit. It is employed to cause the gate's immediate stop. This control must used in an
emergency situation.
Photocell
Input connected to an optical barrier. It detects and signal the passage of persons or vehicles in the area crossed by the gate or in the nearby area.
Photostop
Input connected to an optical barrier. It detects and signal the passage of persons or vehicles in the area crossed by the gate or in the nearby area.
Opening Limit Switch
Input connected to a switch placed outside the unit. The switch operates when the shutter has completed its opening phase.
Closing Limit Switch
Input connected to a switch placed outside the unit. The switch operates when the shutter has completed its closing phase.