Inputs State Optical Signals - AS Torantriebe CTR54 Manuel D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

ENGLISH

6) Inputs state optical signals

During the normal operation of the equipment, the display shows the inputs state in the following way:
FOT - Photocell
The segment of the display goes off when the photocell is covered by the passage of people or cars.
FTS - Photostop
The segment of the display goes off when the optic barrier is covered by the passage of people or cars.
START - Common Start
The segment of the display goes on at the Start command.
PED - Pedestrian Start
The segment of the display goes on at the command of Pedestrian Start.
FC1A - Motor 1 opening limit switch
The segment of the display goes off when the limit switch is enabled.
FC1C - Motor 1 closing limit switch
The segment of the display goes off when the limit switch is enabled.
FC2A - Motor 2 opening limit switch
The segment of the display goes off when the limit switch is enabled.
FC2C - Motor 2 closing limit switch
The segment of the display goes off when the limit switch is enabled.
7) Definitions of Trimmers
RV1 – Slow-down speed and power regulation
It regulates the power supplied to the motors during the operation except at the departure (100% of torque) and during the slowing-down minimum
speed. Rotate the trimmer in clockwise sense to increase the power supplied to the motors. During the programming phase, it regulates the slowing-
down speed of the gate. The regulation of the slowing-down speed is not linear but in jerky way (Total 4). Rotate the trimmer in clockwise sense to
increase the slowing-down speed.
28