10.3.7 Users Page
From menu entry User Configuration it is possible to
manage all users that have access to the device.
Administrator type users can access the complete
configuration of the device.
Users such as Operators, Users and Anonymous have
limited access to the management pages.
Users with limited access can only access the pages:
• Home (move the Pan & Tilt, check the
illuminators, enable the wiper, enable the wash
system, enable the relays and reference the
presets)
• Device Parameters
• Device Statistics
Fig. 77
The password can only contain the following
characters (a-z, A-Z, 0-9, ,._+@%/-()^*[]{}#;~).
Some cameras may not support the aforementioned
set of characters.
10.3.8 Movements Page
From menu entry Movements is possible to control,
via web, all Pan & Tilt parameters.
• Offset Pan: The pan & tilt has a mechanically
defined 0° position. The Offset Pan function allows
the definition of a different 0° position using
software.
• Economy Mode: It reduces the motor's torque
when the Pan & Tilt is at standstill to decrease
consumption. Do not enable in the presence of
strong wind or vibrations.
• Maximum Speed: Sets the maximum manual
speed.
• Ramp Type: This allows you to select the Pan &
Tilt accelerations. (Acceleration/deceleration time:
1=1.1s, 2=0.95s, 3=0.8s, 4=0.5s)
• Speed with Zoom: When enabled, this parameter
automatically slows down the Pan & Tilt speed,
based on the Zoom factor.
MNVCU2_2222_EN
• Tilt Factor: Sets the reduction factor of the tilt axis
manual speed. Movement speed factor calculation:
Tilt axis speed = Tilt nominal speed / Tilt factor.
• Pan Limits: Enables the limits of Pan.
• Pan Start: Sets the start limit of Pan.
• Pan End: Sets the end limit of Pan.
• Tilt Start: Sets the start limit of Tilt.
• Tilt End: Sets the end limit of Tilt.
• Sensitivity: It enables selection of detection
system sensitivity of unwanted Pan and Tilt
movements. If the threshold set is surpassed, the
system will calibrate Pan and Tilt.