7.4.7 Installation of the upper body of
the housing with anti-icing heated glass
and wiper (optional)
Unplug the wiper power cable. Remove the upper
body of the housing by loosening the screws. Slightly
rotate the upper part of the housing for easier
removal of the hinge screws.
Fig. 29
Fit the new upper body in place using the screws
previously removed.
Pay attention to the fixing. Tightening
torque: 1.2Nm.
There are two connectors on the housing card that
allow you to power the heated glass and the wiper
(J16, J17, 7.4.1 Housing board description, page
17). Connect the 2 wires on the upper body of the
housing with the 2 connectors on the housing card.
Fig. 30
Enable the heated glass management (10.3.2
Hardware Configuration Page, page 34).
MNVCU2_2222_EN

7.4.8 Closing the housing

After installation and wiring, close the product again.
Check that the gasket of the housing is present and in
good condition.
Pay attention to the fixing. Tightening
torque: 6Nm.
8 Installation
Never, under any circumstances, make
any changes or connections that are not
shown in this handbook. Failure to follow
the connection instructions that are given
in the handbook may create serious safety
hazards for people and for the installation.
Do not change the wiring in the product
as it is supplied to you. Failure to follow
this instruction may create serious safety
hazards for people and for the installation,
and will also invalidate the guarantee.

8.1 Fixing the base to the support

Remove the base from the unit.
Fig. 31