15 A) Remove the plugs that seal the
frame holes;
B) Position the previously prepared
plate in correspondence with the frame
holes
16 A) Remove the upper plaque in nylon
from the cabinet riser.
B) Using a bit of . max 9 mm, drill in
correspondence with the predisposed
hole on the left side, so as to create a
housing for the pin of the upper hinge
Avoid off-axis or inclined holes.
Drilling depth: min.18 mm max 24 mm.
C) Re-position the nylon plaque in its
new position using the respective
screws
17 At this point, re-mount the now left-
handed door, making sure to first insert
the upper hinge in the hole previously
created and to subsequently position it
slowly in such a way as to insert the
lower pin in the respective hole of the
lower plate unit.
As in dismantling, if difficulties are
encountered.
18 Restore the electric connection, taking
care to rotate the plaque (1) by 180° so
that the words "left door" appear on
the upper part of the plaque itself.
A) Close the connector;
B) Re-insert the cable;
C) Tighten the screws (1)
19 Insert the spring-loading spanner into
one of the holes of the lower pin, rotate
in an anti-clockwise direction so as to
insert the loading pin. When the
operation has been completed, the
door should close automatically. If it is
not sufficiently loaded, move the
loadingpin by one hole