what established by Article 3, paragraph 3 of the same directive.
In the case that the original copy of the Declaration of Product Conformity
provided with the product is lost, it is possible to download a copy by completing
the form found at the following website: http://www.arneg.it/conformity
The performances of these refrigerated cabinets have been determined by means of a
test conducted in compliance to norm UNI EN ISO 23953-2: 2006 in the environmental
conditions that correspond to climatic class 3 (25 °C , 60% R.U.)
Environmental climatic classes as per UNI EN ISO 23953 - 2
Climatic Class
1
2
3
4
5
6
6. Identification - Rating Plate (Rif. 2)
The serial plate with all the characteristic data is placed on the back of the cabinet:
1) Name and address of the manufacturer
2) Name and length of the cabinet
3) Code of the cabinet
4) Serial number of the cabinet
5) Power supply voltage
6) Power supply frequency
7) Absorbed operating current
8) Operating electrical power absorbed in the refrigeration phase (fans+hot
wires+lighting)
9) Operating electrical power absorbed in the defrosting phase (armoured heaters+hot
wires+ fans+lighting)
10) Lighting power (where included)
11) Usable display surface
12) Type of refrigerant fluid used by the system to operate
13) Mass of refrigerant gas loaded in every system (only for cabinets with a built-in
motor)
14) Environmental climatic class and temperature of reference
15) Class of protection against humidity
16) Number of the job order based on which the cabinet has been manufactured
17) Number of purchase order based on which the cabinet has been put in production
18) Year of manufacture of the cabinet
To identify the cabinet in the case technical assistance is requested, communicate:
the product name (2); the serial number (4); the job order number (16).
7. Transport - specialized technician -
The loading-unloading operations must be performed by qualified personnel capable of
checking the weights, the exact lifting points, and the means most suitable both in
terms of safety and load-bearing capacity. The cabinets come with a frame-platform in
wood fixed to the base for their displacement with forklifts. Use a manual or electrical
forklift suitable to lift the cabinet in question, with a nominal capacity greater or equal to
1000 kg.
Always position the loading forks in the points indicated to avoid the risk of
tipping over, always insert the forks all the way through.
NO persons foreign to operations must be present near the lifting area.
Evenly distribute the cabinet weight so as to keep the centre of mass of the
load in balance.
DO NOT use lifting means that have:
30
Dry bulb temp.
Relative Humidity
16°C
22°C
25°C
30°C
40°C
27°C
Dew point
80%
65%
60%
55%
40%
70%
12°C
15°C
17°C
20°C
24°C
21°C
05060130 00 26/04/2012