in environments where explosive gaseous substances are present;
in open air and therefore subjected to atmospheric agents;
near heat sources (direct sunlight, heating systems, incandescence lamps, etc.)
near air currents (near doors, windows, air-conditioning systems, etc.) that exceed
a speed of 0.2 m/sec.
Remove the supports in wood at the base (used for transport) and assemble the
adjustable feet (Rif. 6) positioning them so as to place the cabinet horizontally, aiding
yourself of a level (Rif. 5) to check proper alignment .
Before connecting the cabinet to the electrical line, make sure that the rating plate data
matches the characteristics of the electrical system to which the cabinet must be
attached.
For a correct operation of the cabinet, the room temperature and relative humidity must
not exceed the limits relative to climatic class 3 (+25°C; R.U. 60%) established by the
norms EN-ISO 23953 - 2 with which the counter has been tested.
The cabinet must be assembled in a position tilted toward the wall by at
least 10 mm (Rif. 15)
If the cabinet is displaced, re-check its levelling; an incorrect levelling
compromises operation of the cabinet.
The cabinet must be levelled both at the front and at the back.
Install a maximum of 3 cabinets in channel on the same electrical and
refrigerant power supply line (1 master + 2 slaves)
11.Electrical connection (Rif. 24) - (Rif. 25) - specialized technician -
BEFORE ANY OPERATION REMOVE VOLTAGE TO THE SYSTEM!
system must have a grounding connection!
The systems must be set up in accordance to the norms that regulate
manufacture, installation, use, and maintenance foreseen by the norms in
force in the country where the cabinet is installed.
ARNEG Spa rejects any responsibility toward the user and third parties for
damages caused by breakdowns or malfunctions of the systems arranged
upstream of the cabinet and for damages to the cabinet that stem from causes
directly ascribable to an electrical system malfunction.
The cabinet must be protected upstream with an automatic, omnipolar
magneto-thermal switch having adequate characteristics and which will serve
as the main line disconnecting switch.
It is the Client's responsibility to arrange the electrical power supply line up to the point
of connection to the cabinet. Sizing of the electrical power supply line must be
performed in accordance to the power absorbed by the cabinet (see Technical Data).
Remove all metallic objects worn: rings, watches, bracelets, earrings, etc.
Consult the wiring diagrams before performing the connection.
Check that power supply voltage is the one reported on the rating plate.
Instruct the operator on the position of the switch so that it may be timely reached
in case of an EMERGENCY.
To ensure normal operation, the maximum variation of the voltage must range
between +/- 6% of the nominal value.
Check that the power supply line has wires with an appropriate diameter, that it is
protected against overcurrents, and that the leakages to ground are in compliance
to the norms in force.
If the electrical power supply is interrupted, check that all the electrical devices of
the store can restart without triggering the intervention of the overload protections;
on the contrary, modify the system so as to differentiate activation of the various
devices.
If the power supply cable is faulty or ruined, it must be replaced by the
manufacturer or authority chosen by the same.
The installer must provide the anchoring devices for all the wires in input and outpout
32