PARAMETER
DEFINITION
Auxiliary input 2
16
configuration
Auxiliary output 1
17
configuration
Auxiliary output 2
18
configuration
Not used
19
Safety disabling angle
20
during opening [%]
Master/Slave Connection
21
Opening Time Lag [s]
Master/Slave Connection
22
Closing Time Lag [s]
PHOT OPEN input
23
polarity
PHOT CLOSE input
24
polarity
KEY input polarity
25
RADAR EXT input
26
polarity
RADAR INT input polarity
27
AUX-IN 1 input polarity
28
INSTALLATION MANUAL
MIN.
MAX.
DEFAULT
CUSTOM
0
12
1
 
0
5
0
 
0
5
1
 
0
0
0
 
0
40
0
 
0
100
0
 
0
100
0
 
0
1
1
 
0
1
1
 
0
1
1
 
0
1
0
 
0
1
0
 
0
1
0
 
DESCRIPTION
0 = Input configured as Disabled opening
1 = Input configured as Emergency opening
2 = Input configured as Interlock door with priority
3 = Input configured as Interlock door without priority
4 = Input configured as Lock Release Feedback
5 = Input configured as Lock release
6 = Input configured as Single Command with Master/Slave operating mode
7 = Input configured as Standby. If activated, it sets the door to standby only
with the door in the closed position.
8 = Input configured as wake up from Standby. If activated, it restores
operation following a Standby
9 = Input configured as step-by-step command, meaning that with a pulse
the door opens and stays open, standing by for another pulse to close, again
with the use of Int. Radar or Ext. Radar
10 = input configured as Temporary Stand By. If activated, the door is in stand
by and therefore the closing movement is spring-loaded. If deactivated, the
door works normally.
11 = Input configured as manual operation. If active, the operation of the
selector in the head is disabled.
12 = Input configured as Stop Closed operation. If active, the operation of the
selector in the head is disabled.
0 = Output configured as Sensor supervision
1 = Output configured as Interlock
2 = Output configured as Door State open.
3 = Output configured as Door State closed.
4 = Output configured as Fault
5 = Output configured as Lock command repeat
0 = Output configured as Sensor supervision
1 = Output configured as Interlock
2 = Output configured as Door State open.
3 = Output configured as Door State closed.
4 = Output configured as Fault
5 = Output configured as Lock command repeat
Not used, must be kept at = 0
Safety disabling angle during opening, percentage of total travel
Slave motor opening delay time with respect to master motor. 100ms
increments
Master motor closing delay time with respect to slave motor. 100ms steps
0 = N.O. Normally open
1 = N.C. Normally closed
0 = N.O. Normally open
1 = N.C. Normally closed
0 = N.O. Normally open
1 = N.C. Normally closed
0 = N.O. Normally open
1 = N.C. Normally closed
0 = N.O. Normally open
1 = N.C. Normally closed
0 = N.O. Normally open
1 = N.C. Normally closed
- 33