BFT VISTA SW SXL Instructions D'utilisation Et D'installation page 31

Automations pour portes
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 37
9.2) AUXILIARY OUTPUT CONNECTIONS Fig. N
9.3) CONNECTING DETECTORS/SAFETY SENSORS WITH TESTING DURING
OPENING AND CLOSING Fig. P, Q
10) ARM TYPE SELECTION Fig. H
11) OPERATING PARAMETER MANAGEMENT - DIP SWITCH
DIP
Logic
Default
SW
1
Arm type
OFF
2
LOW ENERGY
OFF
3
PUSH & GO
OFF
4
KEY mode
OFF
OFF
5
Actuator type
ON
6
Operating mode 1
OFF
Operating
7
OFF
mode 2
8
Not used
OFF
* Reduced-speed opening with increased hold time (disabled hold time)
using the disabled opening command (on configurable output) [AUX IN 1, by
setting parameter 15=0 ("Operating parameter management-display" section)].
Subsequent closing is spring operated with obstacle management
** Moving the leaf manually while stationary in the closed position triggers its
automatic opening and closing.
*** Battery-powered panic mode
**** Motor-driven reopening in event of collision during spring-operated closing
****** Use of batteries
WARNING: each DIP variation must be confirmed with a card
RESET by switching it off and then back on.
INSTALLATION MANUAL
Cross out setting
Description
used
OFF
Double lever
ON
Single lever
OFF
Standard
ON
Low Energy *
OFF
Disabled
ON
Enabled **
OFF
Latching
ON
Non-latching
OFF
VISTA SW MXL
ON
VISTA SW SXL
Motor-driven
VISTA SW SXL: OFF
closing
Spring-oper-
VISTA SW SXL: ON
ated closing
Continuous
VISTA SW MXL***: OFF
operation
VISTA SW MXL***: ON
Panic opening
No reopen-
ing when
obstacle is
VISTA SW SXL****:
detected dur-
OFF
ing spring-
operated
closing
Reopening
when obsta-
cle is detected
VISTA SW SXL****: ON
during spring-
operated
closing
VISTA SW MXL*****:
No batteries
OFF
fitted
VISTA SW MXL*****:
Batteries
ON
fitted
11.1) "LOW VOLTAGE" OPERATION
A "low voltage" door (no higher than 1.69 J) must be adjusted so that:
- The leaf minimum closing times (from 90° to 10°) are the same as or higher
than the values shown in Table 1.
- The minimum slow-down time of the leaf while closing (last 10°) must be at
least 1.5 s.
- The force required to keep the leaf still must not exceed 67 N at any point of
the opening or closing manoeuvre (applied to the main closing edge in the
direction of travel);
- In case of an interruption in the power supply or of motor failure, it is possible
to unblock the leaf with a force of less than 67N and open it with no more than
90N (force applied to the main closing edge in the direction of travel).
Note: a static closing force up to 150N is anyway admitted when the opening
between the main closing edge and the stopping edge is ≤8 mm.
Table 1 – Leaf minimum closing times
Leaf width
(mm)
50
750 mm
3,0 s
850 mm
3,0 s
1.000 mm
3,5 s
1.200 mm
4,0 s
To modify the closing speed, see paragraph 12.
Leaf weight (kg)
60
70
80
3,0 s
3,0 s
3,0 s
3,0 s
3,5 s
3,5 s
3,5 s
4,0 s
4,0 s
4,5 s
4,5 s
5,0 s
VISTA SW SXL - VISTA SW MXL
90
3,5 s
4,0 s
4,5 s
5,5 s
- 31

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Vista sw mxl

Table des Matières